Wiring Technical Notes - GE GEC-4VPHUB Installation Sheet

Multi-channel passive transceiver hubs
Table of Contents

Advertisement

Wiring Technical Notes

These technical notes should all be considered prior to installing these devices.
Use point to point unshielded twisted pair wire 24-16 AWG (0, 5-1, 3 mm)
stranded or solid, Category 2 or better.
The video signal may coexist in the same wire bundle as other video,
telephone, data, control signals, or low-voltage power. You can run GE video
signals in or near electromagnetic fields (in accordance with National
Electrical Code, local or other local safety requirements).
DO NOT USE SHIELDED TWISTED PAIR WIRE. Multi-pair (8 pair or more) wires
with an overall shield are fine.
DO NOT USE UN-TWISTED WIRE.
DO NOT place a transmit and a receive signal in the same wire bundle. It
may cause interference.
DO NOT send Up-the-Coax Pan/Tilt/Zoom signals through active (amplified)
GE transmitters or receivers. Passive GE transceivers can transmit video and
Up-the-Coax P/T/Z control signals up to 750 ft. (228 m).
We recommend using short 18 AWG solid wires for ground connections.
GE VPD products follow the EIA/TIA 568 standard. There are two wire color-
code standards: EIA/TIA 568A and EIA/TIA 568B. Either standard can be used
for making connections as long as the RJ-45 jacks at both ends of each
cable follow the same standard.
Measure wire distance by:
1.
Shorting the two conductors together at the far end, and measuring
the loop-resistance by an Ohmmeter.
2.
Use the Loop Resistance table to calculate the distance.
DO NOT connect coax cables longer than 100 ft. (30 M) to the BNC
connectors of any GE UTP equipment.
All measured distances should include any coax cables in the path.
Verify camera current requirements and wire resistance limits for the
maximum distance that power can travel. Use the Power Distance Chart to
verify the wire distance.
GE VPD products require Unshielded Twisted-Pair (UTP) wires Category 2 or
better, 24 AWG (0,5 mm) or thicker.
P/N 1069682 • REV 1.0 • ISS 14APR10
3 of 9