Installation Information / Sleeve Dimensions

Sleeve
Height
Width
Q
14"
19 ¾"
P1†
12 ¼"
18 ½"
P4
17 ½"
26"
P5
17 ½"
26"
P6
13
"
18 ½"
5
8
P7
15"
23
5
8
S
15
"
25
15
15
16
16
M
17
"
25
15
15
16
16
L
20
"
28"
3
16
Sleeve P1 does not have thru-the-wall hole dimensions, as these units are fixed chassis and should not be installed thru-the-wall.
Circuit rating/ Breaker
Model
CP05, CP06, CP08, CP10, CP12 and CP14.
All XQ MODELS.
KS12L10 and KS15L10. SS08L10, SS10L10,
SS12L10 and SS14L10. EQ08L11A. YS09L10.
CP18. KM18L30.
SS12L30, SS16L30, SM18L30A and SM21L30.
CP24. KM24L30. SM24L30 and SL28L30.
ES12L33 and ES16L33. YS13L33.
SL36L30A. EM18L34, EM24L34 and EL36L35A.
YM18L34 and YL24L35.
room air Conditioner Model Identification Guide
FUNCTION
S–Straight Cool
C–Straight Cool
X–Straight Cool
K–Straight Cool
Y–Heat Pump
E–Electric Heat
CHASSIS
Q–Portable
P–Programmable
S–Small Chassis
M–Medium Chassis
L–Large Chassis
Depth
Minimum
Depth
Hood to
Extension
with Front
Louvers
Into Room
21
"
8 ½"
3
8
15"
5"
27
"
8
"
5
7
8
8
29 ¾"
8
"
7
8
20
"
8
"
5
1
8
8
"
22
""
8 ¾"
1
8
"
27
"
8 ¾"
3
8
"
27
"
8 ¾"
3
8
33
"
16 ½"
5
8
Circuit Rating
Breaker or
T-D Fuse
125V - 15A
250V - 15A
250V - 20A
250V - 30A
S L 28 L 3 0 A
Minimum
Window Width
Extension
Outside
Minimum
5 ½"
10 ¾"
26"
3 ½"
10 ¾"
22"
5 ½"
16
"
27"
5
8
5 ½"
19 ½"
27"
4 ½"
11"
22"
4 ½"
12
27"
3
"
16
"
27
1
15
16
16
3
"
16
"
27
1
15
16
16
3
"
18
"
29
3
15
16
16
Plug Face
Wall Outlet
(NEMA#)
Appearance
5 - 15P
6 - 15P
6 - 20P
6 - 30P
MODEL SERIES
APPROXIMATE
BTUS (000) Cooling
Thru-the-wall
Finished Hole
Maximum
Height
42"
14 ¼"
36"
NOT FOR THRU-WALL
42"
17 ¾"
42"
17 ¾"
36"
13
"
7
8
39"
15 ¼"
"
42"
16
"
7
3
8
16
"
42"
18
"
7
3
8
16
"
42"
20
"
7
3
8
8
Window Mounting Kits
TwinTemp Model
EQ08L11A
ES12L33, ES16L33, YS09L10 and YS13L33.
EM18L34, YM18L34 and EM24L34.
EL36L35A and YL24L35.
TWINTEMP
models include accessories for thru-the-wall
®
installation only. Window mounting requires use of optional
accessory kit as listed above.
Letter at end of model number indicates
a modification to an existing model.
0 – Straight Cool and
115V Heat Pump Models
1 – 1 KW heat strip, Nominal
3 – 3 KW heat strip, Nominal
4 – 4 KW heat strip, Nominal
5 – 5 KW heat strip, Nominal
VOLTAGE
1–115 Volts
3–230/208 Volts
Width
20"
26 ¼"
26 ¼"
18 ¾"
23
"
7
8
26
"
3
16
26
"
3
16
28 ¼"
Kit No.
WIKQ
WIKS
WIKM
WIKL

Advertisement

loading