Performance Data; Installation Information/Sleeve Dimensions - Friedrich SQ06N10 Series Service & Parts Manual

Room air conditioners
Hide thumbs Also See for SQ06N10 Series:
Table of Contents

Advertisement

PERFORMANCE DATA

EVAP. AIR TEMP. DEG. F
COOLING
PERFORMANCE DATA**
Discharge Air
57
SQ05N10-A
SQ06N10-A
57
SQ08N10-A
58
SQ10N10-A
53
EQ08N11-A
53
*
Cooling
Model
Capacity Btu
Kühl
®
SQ
05N10
*
5500
SQ
06N10
*
5900
SQ
08N10
7500
*
SQ
10N10
9500
*
Kühl+
Electric Heat
®
EQ08N11
*
7500
As an ENERGY STAR
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
meet the ENERGY STAR
®
Estimated yearly operating cost based on a 2007 national average electricity cost of 10.65 cents per kWh.
Installation Information / Sleeve Dimensions
Sleeve
Height
Width
Q
14"
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
Circuit Rating / Breaker
Model
SQ05N10
, SQ06N10
,
*
*
SQ08N10
, SQ10N10
*
*
EQ08N11
*
Window Mounting Kits
Heat/Cool Models
EQ08 N11
*
Friedrich heat/cool models include accessories for
thru-the-wall installation only. Window mounting requires
use of optional accessory kit as listed above.
6
*
CONDENSER
Discharge Temp Suction Temp Super Heat Sub-Cooling
TEMPERATURE DEG. F
Temp.
Drop F.
23
115
146
23
115
146
23
118
158
22
122
164
27
117
159
Heating
Volts
Cooling
Cooling
Capacity Btu
Rated
Amps
115
4.5
115
4.9
115
6.1
115
8.4
4000
115
6.9
Depth
Shell Depth to
with Front
Louvers
3 8
"
19
"
21
"
8
Circuit Rating
Plug
Breaker or
Face
T-D Fuse
(NEMA#)
125V - 15A
5 - 15P
Kit No.
WIKQ
OPERATING PRESSURES
Suction
63
10
13
158
63
10
13
150
63
12
20
147
58
11
23
136
61
20
19
146
Heating
Heating
Watts
Amps
Watts
COP
514
561
700
969
765
11.2
1290
1.9
Minimum
Minimum
Extension
Extension
Into Room*
Outside*
Minimum** Maximum
"
"
5
10
Wall Outlet
Power Cord
Length (ft.)
Appearance
7
6
ELECTRICAL RATINGS
Locked Rotor
Discharge
Amps Cool Amps Heat
Amps
387
9
387
4.9
415
6.6
428
9.2
411
6.7
11.2
Energy
Estimated
Room Side
Yearly
Moisture
Ratio
Operating
Removal
Circulation
EER
Cost
Pints/HR
10.7
$41
0,5
18.7
$45
0.5
10.7
$56
1.2
9.8
$77
2.1
11.7
$61
1.9
models
®
Thru-the-wall Installation
Window Width
Finished Hole
Height
Width
22"
42"
14 "
(C)
Front
(B)
R-410A
BREAKER FUSE
REF.
Voltage
Charge in
60 Hertz Amps
OZ.
29.0
17.0
115
15
29.0
17.0
115
15
32.0
22.0
115
15
50.0
23.5
115
15
32.0
18.5
115
15
Air
Net
Weight Ship
CFM
Sleeve
Lbs
Wt
190
Q
65
78
190
Q
71
84
240
Q
71
84
240
Q
75
88
175
Q
72
84
C
US
Max. Depth
20"
8 "
SIDE VIEW

Advertisement

Table of Contents
loading

Table of Contents