SVR-I2U-R2312 Server Installation and
Maintenance Guide
P/N 300-013-550
REV 02
June, 2013
This document describes installation and maintenance procedures for the SVR-I2U-R2312
server. This server has slots for twelve 3.5-inch drive assemblies. Some server components
are replaceable as field replaceable units (FRUs). Refer to your product documentation for
information on which components are FRUs. Before attempting to perform hardware service
procedures, review your service contract because replacement of some server components
by unauthorized personnel may void service warranties.
server............................................................................................. 14
server.................................................................................................20
requirements.................................................................... 2
cabinet.................................................................................3
assembly.............................................................................. 15
module............................................................................19
cabinet.................................................................31

Advertisement

loading
Need help?

Need help?

Do you have a question about the SVR-I2U-R2312 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EMC SVR-I2U-R2312

  • Page 1: Table Of Contents

    REV 02 June, 2013 This document describes installation and maintenance procedures for the SVR-I2U-R2312 server. This server has slots for twelve 3.5-inch drive assemblies. Some server components are replaceable as field replaceable units (FRUs). Refer to your product documentation for information on which components are FRUs.
  • Page 2: Technical Information And Requirements

    EMC provides a power and weight calculator at http:// powercalculator.EMC.com. Use this calculator to refine the power and heat values in the table below to more-closely match the specific server hardware configuration. Ensure that the server installation site meets the requirements for your configuration.
  • Page 3: Installing The Server In A Cabinet

    Rating label on the chassis. For additional information, refer to the preparation/planning guides for your specific site and cabinet. Operating limits The ambient temperature specification is measured at the front bezel inlet. The site must have air conditioning of the correct size and placement to maintain the specified ambient temperature range and offset the heat dissipation listed in the table that follows.
  • Page 4 We suggest that you use a cabinet that has dual power distribution units, one on each side. We recommend that you use cabinet anti-tip devices, especially if you are installing or removing a server in the upper half of the cabinet when the lower half is empty. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 5 Verifying the mounting kit parts Verify that the server mounting kit includes the parts listed in the table that follows. Table 5 Mounting kit parts Component 2 universal rail assemblies Attach back to front on either side between (consists of slide rails for connection to the cabinet channels cabinet and inner rails for connection to server)
  • Page 6 4. Secure the alignment post assembly in place with the screw that you removed. The screw goes in the hole opposite the hole from which you removed it. Figure 1 Switching from round rail alignment posts to square alignment posts CL4951 EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 7 Removing inner rails from the rail assemblies Perform the procedure that follows on each rail assembly. Refer to Figure 2 on page 7 while performing the procedure. Procedure 1. Slide the inner rail out from the slide rail as far as possible. 2.
  • Page 8 Select the 2 U (3.5 in) of cabinet space for the server (Figure 4 on page Figure 4 Location for the rails in the 2U space for the server CL5102 Install each slide rail in the cabinet using the procedure that follows. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 9 Procedure 1. From the front of the cabinet, align rail alignment posts with the rear channel holes for the selected cabinet space for the server, and insert the alignment posts securely into the holes (Figure 5 on page An audible click indicates that the connection is secure. Figure 5 Inserting rail alignment posts into rear channel holes CL5090 2.
  • Page 10 When installing the server in the cabinet, do not pick the server up by its power/control module and do not push on its power/control module. This module is on the right side of the front of the server. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 11 Procedure 1. On each slide rail bring the ball bearing retainer assembly fully to the front, so it rides onto the security knob (Figure 8 on page 11). Figure 8 Correct location for ball bearing retainer assembly CL5092 2. From the front of the cabinet, align the inner rails attached to the server with the white plastic guide block on the front inside of each slide rail (Figure 9 on page 11).
  • Page 12 Figure 11 Inserting the server in the cabinet CL5006 6. To further secure the rail assembly and server in the cabinet, insert and tighten a small stabilizer screw directly behind each bezel latch (Figure 12 on page 13). EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 13 Figure 12 Installing the stabilizer screws CL5008 Connecting cables Procedure 1. Plug the power cords into the power supplies and connect these cords to AC power sources as described in the documentation for your product. 2. Attach any I/O cables as described in the documentation for your product. Installing the bezel Bezels are application specific, and may not appear as shown.
  • Page 14: Maintaining The Server

    Regardless of the product in which the server is used, the power supply modules are hot-swappable; that is you can replace a power supply module while the server is running. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 15: Replacing A Disk Drive Assembly

    You should not remove a faulty FRU until you have a replacement available. When you replace FRUs, you can inadvertently damage the sensitive electronic circuits in the equipment by simply touching them. Electrostatic charge (ESD) that has accumulated on your body discharges through the circuits. If the air in the work area is very dry, running a humidifier in the work area will help decrease the risk of ESD damage.
  • Page 16 Consult your product documentation on how to identify a faulted disk assembly in the server. A faulted disk drive assembly may have an amber LED indicator on its carrier, which is visible when you remove the server’s bezel. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 17 Removing the bezel The front of the server may be covered by a bezel. Bezels are application specific, and may not appear as shown. Bezels may include a key lock. If the server has a bezel, remove it. Refer to Figure 14 on page 17 while performing the procedure that follows.
  • Page 18 1. Pushing on the ends, not the middle, of the bezel, press the bezel onto the latch brackets until is snaps into place. 2. If the bezel has a key lock, lock the bezel with the provided key and store the key in a secure place. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 19: Replacing A Power Supply Module

    Figure 17 Installing the bezel CL5009 Replacing a power supply module The power supply modules are accessible from the rear of the server. Before you begin the procedure below to replace a faulted power supply module, review the section on handling field replaceable units (FRUs).
  • Page 20: Replacing The Server

    2. Disconnect the cables from the server. 3. Remove the bezel from the server. 4. Remove the server from the cabinet. 5. Remove the inner rails from the server. 6. Unpack the replacement server. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 21 7. Attach the inner rails to the replacement server. 8. Install the replacement server on the rails in the cabinet. 9. Reconnect the cables that you removed from the original server to the replacement server. 10. Reinstall the bezel on the replacement server. 11.
  • Page 22 Para evitar daños personales o en el equipo, el compartimento no debe levantarse ni instalarse en el bastidor sin la ayuda de un elevador mecánico o de otra persona. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 23 When removing the server from the cabinet, do not hold the server up by its power/ control module, which is on the right side of the front of the server. Procedure 1. Remove the stabilizing screw behind the latch bracket on each side (Figure 21 on page 23).
  • Page 24 2. When the connections studs are in the large end of the rail notches, release the metal latch and pull the inner rail away from the server. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 25 Figure 24 Releasing the inner rails from the server CL5005 Unpacking a part Procedure 1. Attach an ESD wristband to your wrist and the enclosure in which you are installing the part. 2. Unpack the part and place it on a static-free surface. 3.
  • Page 26 Figure 25 Attaching an inner rail to the server CL5004 EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 27 Installing the server on the rails in the cabinet The enclosure is heavy and should be installed into or removed from a rack by two people. To avoid personal injury and/or damage to the equipment, do not attempt to lift and install the enclosure into a rack without a mechanical lift and/or help from another person.
  • Page 28 3. Slide the server into the cabinet so the inner rails extends over the plastic guide blocks and the first part of the ball bearing retainer assemblies (Figure 28 on page 29). For clarity Figure 28 on page 29 shows the inner rail without the server attached. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 29 Figure 28 Inner rail over the first part of ball bearing retainer assembly CL5094 4. Once the inner rails are properly engaged with the ball bearing retainer assemblies, push the server into the cabinet until the slide rails are engaged and locked. An audible click indicates that the slide rails are engaged and locked.
  • Page 30 1. Pushing on the ends, not the middle, of the bezel, press the bezel onto the latch brackets until is snaps into place. 2. If the bezel has a key lock, lock the bezel with the provided key and store the key in a secure place. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 31: Removing The Slide Rails From The Cabinet

    Figure 31 Installing the bezel CL5009 Powering up the server Power up the server as described in the documentation for your product. Removing the slide rails from the cabinet If you ever need to remove the rails from the cabinet, use the procedure that follows. Procedure 1.
  • Page 32 2. Release each rail from the channels (Figure 33 on page 33): a. At each rail end, push and hold the alignment posts together. b. Slide the rail out of the channel, and remove it from the cabinet. EMC SVR-I2U-R2312 Server Installation and Maintenance Guide 0...
  • Page 33 Figure 33 Releasing the rail from the cabinet channels Rear CL4856 Removing the slide rails from the cabinet...
  • Page 34 2012-2013 EMC Corporation. All rights reserved. Published in USA. Published June, 2013 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose.