General Information - Napoleon BISZ300FT Manual

Infrared side burner
Table of Contents

Advertisement

Available languages

Available languages

4

General Information

EN
This gas barbecue is CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 1.6a-2006
AND ANSI Z21.58a -2006 RESPECTIVELY FOR outdoor gas grills and should be installed TO CONFORM WITH
LOCAL CODES. In the absence of local codes, the installation must conform with either ANSI Z223.1 / NFPA
54, Natural Gas and Propane Installation code, CSA B149.1 or Propane Storage and Handling Code, B149.2.
If a rotisserie motor is used, it must be electrically grounded in accordance with local codes or, in absence
of local codes, with the current CSA C22.1 Canadian electrical code in Canada or the National Electrical
Code, ANSI/NFPA 70 in the United States.
California Proposition 65: The burning of gas fuel creates by-products, some of which are on the list as
substances known by the State of California to cause cancer or reproductive harm. When cooking with
gas, always ensure adequate ventilation to the unit, to minimize exposure to such substances.
Propane Cylinder Specifications
WARNING!
may occur.
A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never
use a cylinder with a damaged valve. Use only a propane supply cylinder constructed and marked in
accordance with the specifications for LP-gas cylinders of the National Standard of Canada, CAN/CSA-b339,
Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable or
the Specifications for LP-Gas Cylinders of the U.S. Department of Transportation (D.O.T.). This appliance
has been designed for use with a 20 lb. (9.1 kg) size propane cylinder only (not supplied).
The propane cylinder must be provided with a cylinder connection device compatible with the connection
for outdoor cooking appliances. The propane cylinder must be provided with a shut-off valve terminating
in a propane cylinder valve type QCC1, and a safety relief device having direct communication with the
vapor space of the cylinder. The cylinder supply system must be arranged for vapor withdrawal and the
cylinder shall include a collar to protect the cylinder valve. The cylinder shall incorporate a listed OPD
(overfill protection device). Do not store a spare LP-gas cylinder under or near this appliance. Never fill
the cylinder beyond 80 percent full.
The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas
supply piping system during an pressure testing of that system at test pressures in excess of 0.5 psi (3.5
kPa).
The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
Gas Hook-Up Instructions
WARNING!
serviced by a qualified installer to local codes.
WARNING!
Built In Propane Gas Hook-Up: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instructions. Do not use hose to connect the unit. It must be
connected with rigid pipe, copper tube or an approved flexible metal connector. The installation must
comply with CAN B149.1 Natural Gas and Propane installation code in Canada, or to the National Fuel
Gas code, ANSI Z223.1 in the United States. The minimum recommended piping size is NPS 1/2" for
rigid pipe, and 1/2" OD for copper tubing (based on a 20 ft. run). Longer runs may require larger sizes
to conform with local codes or to conform with CAN B149.1. Propane Gas Installation Code in Canada or
to the National Fuel Gas Code, ANSI Z223.1 in the United States. A flexible metal connector is included
to simplify the installation of the unit. Connect this connector to the 3/8" flare fitting on the end of the
manifold. Connect the other end of the connector to the gas piping. Ensure that the connector does not
pass through a wall, floor, ceiling or partition, and is protected from damage. Do not use hose to connect
the unit. For the BISZ300, the gas supply must be connected to the 3/8" flare elbow fitting located under
the right hand side of the control panel. For the BISB245, the gas supply must be connected to the 3/8"
flare fitting located under the center of the control panel. If installing a side burner, a separate line must
be branched off to the side burner unit and enter the side burner opening at the specified location. If the
enclosure is to house a propane cylinder, the tank portion of the enclosure must be ventilated according
to local codes, and must not have communication with the cavity used to enclose the gas grill. A propane
tank can not be stored below the gas grill.
www.napoleongrills.com
If these instructions are not followed exactly, a fire causing death or serious injury
This grill is designed for non-combustible enclosures only, and must be installed and
Cabinet frame and cabinet must be made from non-combustible material.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bisb245Bisz300Bisz300ssBisz300pftBisz300nftBisz300n-1

Table of Contents