input power connection

Warning
primary power
Three-phase input power must be provided from a line (wall) disconnect switch that contains fuses or circuit
breakers in accordance to local or state regulations.
Sizes per National Electrical Code for a 90° C (194˚ F) rated copper conductors @ 40° C (104˚ F) ambient. Not
more than three conductors in raceway or cable. Local codes should be followed if they specify sizes other
than those listed above.
To estimate the input current for a wide range of output conditions, use the formula below.
Input current =
notice
28
installation
electric shocK can Kill!
proViDe maximum protection against electrical shocK.
Before anY connections are maDe insiDe the machine, open
the line Wall Disconnect sWitch to turn poWer off.
Recommended input conductor and line fuse sizes:
input requirements
at rated load
Volts
amperes
200
115
230
96
380 CCC
60
400 CE
57
460
50
575
43
Rated load is output of 200A at 160V
(V arc) x (I arc) x 0.73
(V line)
Dedicated power line may be necessary.
plasma unit is equipped with line voltage compensation but to
avoid impaired performance due to an overloaded circuit, a dedi-
cated power line may be required.
input &
time
ground
Delay
copper con-
line fuse
ductors
aWg / mm2
amperes
2/0 AWG
150
1 AWG
125
25mm2
80
25mm2
75
4 AWG
70
4 AWG
60