Hoshizaki SRK-15J Instruction Manual page 16

Modular crescent cuber including condensing unit
Table of Contents

Advertisement

7) Dispenser Unit: Seal the inner perimeter of the icemaker evaporator section to the
dispenser unit adapter kit with RTV-748 sealant (provided) or equivalent. See Fig. 9.
Make sure the inner perimeter sealant meets the outer perimeter sealant and that there
are no gaps.
The following locations must be properly sealed with RTV-748 sealant or
equivalent. Otherwise, water leakage may occur which could result in a slip hazard
and costly water damage.
• Contact points between the dispenser unit and the dispenser unit adapter kit.
• Contact points between the icemaker evaporator section and the dispenser unit
adapter kit.
• Outer perimeter contact points between the dispenser unit and icemaker.
WARNING
Seal the Inner Perimeter with RTV-748 Sealant or Equivalent.
Make sure the inner perimeter sealant meets the outer
perimeter sealant and that there are no gaps.
Dispenser
Unit
Fig. 9
16
Icemaker
Evaporator
Section