Outdoor Fan Speed Control; Vertical Airflow Direction Control - Panasonic CS-A9DKA Service Manual

Table of Contents

Advertisement

CS-A9DKA CU-A9DKA / CS-A12DKA CU-A12DKA /
• Auto Fan Speed during Heating operation.
1. Indoor fan will rotate in the range of SLo → Me according to the heat exchanger temperature.
8.6.3.
Manual Fan Speed Control
• Manual fan speed adjustment can be carried out by using the Fan Speed selection button at the remote control.
• There are 3 types of fan speed settings: Lo, Me, Hi.
8.7.

Outdoor Fan Speed Control

• There is only one speed for outdoor fan motor.
• When the air conditioner is turned on, the compressor and the outdoor fan will operate simultaneously.
• Likewise, both compressor and outdoor fan will stop at the same time if the unit is turned off.
8.8.

Vertical Airflow Direction Control

8.8.1.
Auto Control
(Cooling and Soft Dry Operation condition)
• When the vertical airflow direction is set to Auto using the
remote control, the louver swings up and down as shown in
the diagram.
• When stop operation using the remote control, the
discharge vent is reset, and stop at the closing position.
• During Cooling operation or Soft Dry operation, indoor fan
motor may stop to rotate at certain periods. At that
condition, the louver will stop swinging and rest at the upper
limit.
• During Anti-dew condensation prevention, Airflow Direction
Auto-control angle change from 0°-32° to 20°-30° under
Cooling and Soft Dry operation mode.
Cooling and Soft Dry Operation
30