Panasonic CS-A9DKA Service Manual page 32

Table of Contents

Advertisement

CS-A9DKA CU-A9DKA / CS-A12DKA CU-A12DKA /
• Vertical Airflow Direction:-
− In "Manual" setting, the vane will automatically shift down 5° lower than previous setting.
− In "Auto" setting, the vane will automatically shift between upper and lower limit depending on the intake air temperature
as Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5° downward.
• Powerful operation stops when:-
− Powerful operation has operate for 15 minutes.
− Powerful button is pressed again.
− Quiet button is pressed.
− Stopped by OFF/ON operation button.
− Timer OFF activates.
− Operating mode is changed.
32