3-4
Dell PowerEdge 4200 Systems Service Manual
Table 3-2. System Error Messages
Message
Embedded
server man-
agement
firmware
download
failed
Incorrect
drive A type
- Run Setup
Incorrect
drive B type
- Run Setup
Invalid CPU
speed
detected -
check jump-
ers
Invalid CPU
speed
detected -
Check speed
jumpers.
System
halted.
Keyboard
controller
error
Cause
The embedded
server management
memory may be
temporarily
corrupted.
The installed dis-
kette drive type does
not match the dis-
kette drive type in
CMOS.
The microprocessor-
speed jumper plug
may be absent or
installed on the
wrong pins.
The microprocessor
speed detected is not
valid.
A cable or connector
may be loose, or the
keyboard controller
may be faulty.
(continued)
Action
Turn off the system to
clear the memory, and
then restart the sys-
tem.
Run the System Setup
program to correct the
diskette drive type.
Check the micropro-
cessor speed jumpers.
Check the micropro-
cessor speed jumpers.
Check the keyboard
cable and connector
for proper connection.
If the problem per-
sists, run the Key-
board Test Group in
the system diagnos-
tics to determine
whether the keyboard
or keyboard controller
is faulty.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents