Cooling Fan In Upper Power Supply Bay; Figure 4-12. Removing Fan In The Upper Power Supply Bay - Dell PowerEdge 4200 Service Manual

Dell poweredge 4200 servers: service manual
Hide thumbs Also See for PowerEdge 4200:
Table of Contents

Advertisement

4-12
Dell PowerEdge 4200 Systems Service Manual
C
ooling Fan in Upper Power Supply Bay
WARNING: Only trained service technicians should perform this proce-
dure. Do not remove the left computer cover with the power on unless
you are replacing a cooling fan. (Never remove the right computer cover
with the computer power on. There are high voltages in this area that can
cause bodily harm.) Also, do not touch or attempt to service any compo-
nents other than the cooling fan using this procedure.
screws (3)

Figure 4-12. Removing Fan in the Upper Power Supply Bay

1. Remove both computer covers.
See "Computer Covers" found earlier in this chapter.
CAUTION: See "Precautionary Measures" at the beginning of this
chapter.
2. Disconnect the cooling fan's power cable from the fan connector on the
system board and feed the cable through the hole in the top of the
power supply bay.
3. Remove the screw on the left side of the chassis that holds the metal fan
carrier.
fan power cable
fan assembly

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents