PROBLEM
Appliance is not connected to a power
supply.
Appliance
does not
The appliance is turned off.
operate.
Tripped circuit breaker or a blown fuse.
The temperature is not set correctly.
The ambient temperature could require a
lower temperature setting.
The door was opened too often.
Appliance is
The door was not closed completely.
not cold
Door is not hermetically sealed.
enough.
The condenser is too dirty.
The ventilation opening is blocked or too
dusty.
The room temperature is higher than
average.
A large number of bottles or cans has
Appliance
been added to the unit.
turns itself
on and off
The door is open too often.
frequently.
The door is not closed completely.
The door gasket does not seal properly.
The appliance is not properly leveled.
Vibrations
The rattling noise may come from the flow of the refrigerant, which is normal. As
each cycle ends, you may hear gurgling sounds caused by the flow of refrigerant
The
in your appliance.
appliance
If temperature fluctuations occur, the contraction and expansion of the inner walls
seems to
may cause popping and crackling noises.
make too
much noise.
The appliance is not properly level.
The appliance is not properly level.
The door will
not close
The door was reversed and not properly
properly.
installed.
The gasket is dirty.
The shelves are out of position.

TROUBLESHOOTING

POSSIBLE CAUSE
Connect the appliance.
Switch on the appliance.
Switch on circuit breaker or replace
fuse.
Check the set temperature.
Set a lower temperature.
Do not open the door more often than
necessary.
Close door properly.
Check the door seal and clean or
replace.
Clean the condenser when necessary.
Clear the obstructions and clean off
the dust.
Put the appliance in a cooler place.
Leave the appliance to work for a
while until the set temperature has
been reached.
Do not open the door more often than
necessary.
Close door properly.
Check the door seal and clean or
replace.
Level the appliance with the adjustable
feet.
Level the appliance with the adjustable
feet.
Level the appliance with the adjustable
feet.
Check the door hinge and reassemble
correctly.
Clean the door gasket.
Check the shelves and refit correctly.