Problems With Your Appliance; Troubleshooting Guide - Summit ALFZ51 Instruction Manual

Single-zone freezer
Table of Contents

Advertisement

You can solve many common problems easily, saving you the cost of a service call. Try the suggestions below
to see if you can solve the problem before calling SUMMIT APPLIANCE.
To reach SUMMIT's customer service call:
PROBLEM
The Appliance does
not operate.
The Appliance is not
cold enough.
The Appliance turns
itself on and off
frequently.
The light does not
work.
Vibrations
The appliance
The rattling noise may come from the flow of the refrigerant, which is normal. As each cycle ends, you may hear
seems to make too
gurgling sounds caused by the flow of refrigerant in your appliance.
much noise.
If temperature fluctuations occur, the contraction and expansion of the inner walls may cause popping and
crackling noises.
The door will not
close properly.
Display "E1", "E2",
"E3", "E4".

PROBLEMS WITH YOUR APPLIANCE

(800) 932-4267 or visit:

TROUBLESHOOTING GUIDE

POSSIBLE CAUSE
The unit defrosts automatically in normal operating
conditions.
The appliance is turned off.
Tripped circuit breaker or a blown fuse.
The temperature is not set correctly.
The ambient temperature could require a lower
temperature setting.
The door was opened too often.
The door was not closed completely.
Door is not hermetically sealed.
The condenser is too dirty.
The ventilation opening is blocked or too dusty.
The room temperature is higher than average.
A large number of bottles has been added to the unit.
The door is open too often.
The door is not closed completely.
The door gasket does not seal properly.
Appliance is not connected to a power supply.
Tripped circuit breaker or a blown fuse.
The light was switched off on the control panel.
The appliance is not properly leveled.
The appliance is not properly leveled.
The appliance is not properly leveled.
The door was reversed and not properly installed.
The gasket is dirty.
The shelves are out of position.
"E1" or "E2" indicates that the air temperature sensor
has failed.
"E3" or "E4" indicates that the defrost sensor in the
evaporator has failed.
www.summitappliance.com/support
Connect the appliance.
Switch on the appliance.
Switch on the circuit breaker or replace the fuse.
Check the set temperature.
Set a lower temperature.
Do not open the door more often than
necessary.
Close the door properly.
Check the door seal and clean or replace it.
Clean the condenser when necessary.
Clear the obstructions and clean the dust.
Put the appliance in a cooler place.
Leave the appliance to work for a while until the
set temperature has been reached.
Do not open the door more often than
necessary.
Close door properly.
Check the door seal and clean or replace.
Connect the appliance.
Switch on the circuit breaker or replace the fuse.
Switch on the light.
Level the appliance with adjustable feet.
Level the appliance with adjustable feet.
Level the appliance with the adjustable feet.
Check the door hinge and reassemble correctly.
Clean the door gasket.
Check the shelves and refit correctly.
Call for service.
10