  • Page 1 PSBEN 10A12C v.1.0 PSBEN 13,8V/10A/17Ah/EN Buffer, switched mode power supply unit. Edition: 3 from 20.11.2012 Supersedes the: 2 from 14.09.2012 edition...
  • Page 2: Table Of Contents

    PSBEN10A12C CONTENTS 1. FUNCTIONAL REQUIREMENTS OF THE PSU COMPLIANT WITH PN-EN 50131-6.... 3 2. TECHNICAL DESCRIPTION........................4 2.1. G ................................4 ENERAL DESCRIPTION 2.2. B ..................................4 LOCK DIAGRAM 2.3 D PSU’ ......................5 ESCRIPTION OF S COMPONENTS AND CONNECTORS 3. OPERATING STATUS INDICATION....................7 3.1.
  • Page 3: Functional Requirements Of The Psu Compliant With Pn-En 50131-6

    PSBEN10A12C Features: • PN-EN50131-6 compliance, grades 1÷3 and II • jumper selectable battery charging current environmental class 0,6A/1,5A/2,2A/3A • mains supply of 230VAC • remote test of the PSU (additional module required) • uninterrupted voltage of 13,8VDC • START button for battery activation •...
  • Page 4: Technical Description

    PSBEN10A12C 2. Technical description. 2.1. General description. The buffer power supply has been designed in accordance with the requirements of the PN-EN 50131-6 standard, grade 1÷3 and II environmental class. It is intended for an uninterrupted supply to alarm system devices requiring stabilized voltage of 12V/DC (+/-15%).
  • Page 5: Description Of Psu's Components And Connectors

    PSBEN10A12C 2.3 Description of PSU’s components and connectors. Table 1. Elements of the PSU pcb (see Fig. 2). Element no. Description PANEL – optical indication connector ; pin - adjustment of battery protection function UVP • battery protection (disconnection) off •...
  • Page 6 PSBEN10A12C Fig. 2. The view of the PSU’s pcb. Table 2. PSU elements (see fig. 3). Element no. Description Insolation transformer PSU board (tab.1, fig.2) TAMPER; micro-switch (contacts) of tamper resistance (NC) fuse in the supply circuit (230 V AC)
  • Page 7: Operating Status Indication

    PSBEN10A12C Fig.3. The view of the PSU. 3. Operating status indication. 3.1. Control panel. The PSU is equipped with a panel with buttons and an LED display which enables reading the basic parameters of the device. The buttons are for selecting and approving a certain parameter that is to be displayed.
  • Page 8 PSBEN10A12C Table 3. A description of the buttons and LEDs of the LED panel. - parameter selection - selection approval - red LED – indicates presence of the AC voltage - red LED – indicates overload of the PSU - red LED –...
  • Page 9: Overview Of Current Failures

    PSBEN10A12C 3.2 Overview of current failures. If any incorrect electrical parameters occur, the PSU will signal the failure by illuminating an appropriate LED on the panel or by activating an acoustic indication (provided it has not been switched off). After pressing the ‘OK’...
  • Page 10: Input Of Collective Failure: Ext In

    PSBEN10A12C - high battery voltage Uaku>14V (during battery test) - failure of the battery charging circuit - polymer fuse PTC activation - exceeding the PSU nominal current - failure in the battery charging circuit - activation of the over voltage protection OVP The technical outputs have been implemented with galvanic isolation between the PSU’s systems and the...
  • Page 11: Battery-Assisted Operation

    PSBEN10A12C Fig. 9. Example of a connection with the fuse module: AWZ535 or AWZ536. 4. Battery-assisted operation. 4.1. Running the PSU from the battery. The PSU has been equipped with two buttons on the pcb board which enable running or disconnecting the PSU during battery-assisted operation.
  • Page 12: Standby Time

    PSBEN10A12C 4.4. Standby time. The standby time during batter-assisted operation depends on: battery capacity, battery charge level and load current. In order to keep the standby time, the current drawn from the PSU during battery-assisted operation should be limited. Characteristics for a 17Ah/12V SLA:...
  • Page 13: Remote Monitoring (Option: Wi-Fi, Ethernet, Rs485, Usb)

    PSBEN10A12C 5. Remote monitoring (option: Wi-Fi, Ethernet, RS485, USB). The PSU has been adjusted to operate in a system that requires a remote control of the parameters in a monitoring centre. Transmitting data concerning PSU status is possible due to an additional, external communication module that is responsible for communication in Wi-Fi, Ethernet or RS485 standard.
  • Page 14: Usb-Ttl Communication

    PSBEN10A12C Fig. 12. RS485 communication with the use of the interfaces: ”INTR” and ”INTUR”. 5.4 USB-TTL communication. If the PSU does not cooperate with any of previously mentioned network and the access to the parameters’ adjustment and memo readings are necessary, the USB-TTL ”INTU” needs to be used. This interface allows direct connection between the computer and the PSU and it is recognisable by the operating system as a virtual COM port.
  • Page 15: Technical Specifications

    PSBEN10A12C The main panel of the program has been formulated in such a way that it is possible to divide it into smaller areas, depending on the number of power supplies. The program enables both a visualisation and an analysis of the received data. Exceeding of the acceptable parameters is indicated by highlighting in red the appropriate area or by twinkling of the indicator.
  • Page 16: Psu' S Factory Settings

    PSBEN10A12C Voltage ’on’ – 10 ÷ 30V DC EXT IN technical input Voltage ’off’ – 0 ÷ 2V DC Level of galvanic isolation: 1500V - LEDs on the PSU’s pcb, - LED panel • output current readings Optical indication: •...
  • Page 17: Installation

    PSBEN10A12C 7. Installation. 7.1 Requirements. The buffer PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC interference and low-voltage installations. The unit should be mounted in confined spaces, in accordance with the II environmental class, with normal relative humidity (RH=90% maximum, without condensation) and temperature from -10°...
  • Page 18: Operation And Use

    PSBEN10A12C 7. Switch on the ~230V AC supply (red AC diode and green AUX diode should be lit). 8. Check the output voltage (the PSU voltage without load and without a battery should amount to 13,7 V ÷ 13,9 V, with a battery or during battery charging process: 11,0 V÷13,8 V).
  • Page 19: Psu Failure Codes

    PSBEN10A12C 9. PSU FAILURE CODES. Failure LED indication Technical Acoustic Fault description Causes code outpust indication actvation EPS FLT - No AC mains Battery-assisted 1 beep supply operation per 10s - Faulty main fuse MAIN PSU FLT PTC polyswitch...
  • Page 20 GENERAL WARRANTY CONDITIONS 1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a five-year warranty for the equipment, , counted from the device’s production date. 2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such...