Page 1
Model No. DC5370 Owner’s Manual Wall Mount Dust Collector QUESTION... 1•847•780•6120 Visit us on the web at www.powertecproducts.com You will need this manual for safety instructions, operating procedures, and warranty. Put it and the original sales invoice in a safe, dry place for future reference.
SAFETY RULES • Keep children out of the work area. Ensure your work WARNING shop is child-proof. Use padlocks, master switches or For your own safety, read and understand all warnings remove switch keys to prevent any unintentional use of and operating instructions before using any tool or power tools.
SPECIFIC SAFETY INSTRUCTIONS • Never operate the dust collector with all blast WARNING gates closed. Read and understand the instruction manual before • Turn machine off, disconnect power cord and ensure all operating the dust collector. Basic precautions listed moving parts have stopped completely before changing below should always be followed when using your dust or emptying the bags.
• If mounting to a framed wall attach the mounting Figure 2 bracket to a support board. Attach the support board with lag screws (not supplied). Flange Bolt 4. Hang the dust collector onto the wall mounting bracket. 5. Place the adhesive foam strip (supplied) around the Wall Mount Bracket dust collector outlet port.
GROUNDING INSTRUCTIONS Extension Cord Length Wire Size…………….. A.W.G. WARNING Up to 50 ft…………… 14 gauge Improper connection of equipment grounding conductor NOTE: Using extension cords over 50 ft. long is not can result in the risk of electrical shock. Equipment recommended.
OPERATION BASIC OPERATIONS Figure 6 ON/OFF Switch On/Off Switch The keyed switch is intended to prevent unauthorized use of the dust collector. Yellow Switch 1. To turn the dust collector ON insert the yellow key into the key slot in the center of the switch. 2.
MAINTENANCE GENERAL MAINTENANCE LUBRICATION The sealed bearings in the motor have been WARNING permanently lubricated at the factory. They require no further lubrication. Make sure the machine is turned off and the cord is MACHINE STORAGE disconnected from the power source before servicing and removing/replacing any components on the machine.
TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Motor will not start 1. Low voltage 1. Check power line for proper voltage 2. Open circuit in motor or loose 2. Inspect all lead connections on motor for loose or connections open connection 3.
WALL MOUNT DUST COLLECTOR PARTS ILLUSTRATION WALL MOUNT DUST COLLECTOR PARTS LIST Key No. Part No Description DC5370001 Main housing DC5370002 Inlet cover 4" DC5370003 Impeller 10" DC5370004 Motor DC5370005 Impeller washer DC5370006 Spring washer 1/4" DC5370007 Cap screw M6 x 30 DC5370008 Phillip HD tp screw M5 x10 DC5370009...
30- DAY SATISFACTION GUARANTEE POLICY During the first 30 days after the date of purchase, if you are dissatisfied with the performance of this POWERTEC tool for any reason, you may return the tool to the retailer from which it was purchased for a full refund or exchange. You must present proof of purchase and return all original equipment packaged with the original product.
Page 12
Southern Technologies, LLC Waukegan, IL 60087...