Abit NI8 SLI Series User Manual page 36

Ntel pentium 4 system board socket 775
Table of Contents

Advertisement

3-6
#
Voltage Monitoring:
Click <Enter> key to enter its submenu:
OC Guru
(*)CPU Core Voltage
(*)DDR Voltage
(*)DDR VTT Voltage
(*)CPU VTT 1.2V Voltage
(*)NB 1.4V Voltage
(*)SB 1.5V Voltage
(*)ATX +12V(24-Pin Connector)
(*)ATX +12V(4-Pin Connector)
(*)ATX +5V
(*)ATX +3.3V
(*)ATX 5VSB
↑↓:Move Enter:Select +/-/PU/PD:Value
All Voltages:
These items display the voltage of each element.
!
Shutdown Enable:
Use <Space> key to enable system shutdown function. If the voltage of corresponding element is
higher/lower than the high/low limit, the system would automatically shutdown.
!
Beep Enable:
Use <Space> key to enable warning beeps function. If the voltage of corresponding element is
higher/lower than the high/low limit, warning beeps will sound.
!
High/Low Limit:
These items set the high and low voltage limit.
NOTE: The value of high limit must be set above the one of low limit.
NI8 SLI Series
µGuru Utility V0.09
ABIT EQ
Voltage Monitoring
Reading Shutdown
1.550V
2.70V
1.35V
1.22V
1.45V
1.55V
11.77V
11.71V
5.03V
3.39V
5.06V
Beep
Enable
Enable
(*)
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
( )
(*)
F10:Save ESC:Exit
Chapter 3
High
Low
Limit
Limit
1.89V
1.00V
2.90V
2.10V
1.55V
1.05V
1.45V
0.95V
1.70V
1.10V
1.80V
0.20V
3.00V
9.60V
14.40V 9.60V
6.00V
4.00V
3.95V
2.65V
6.00V
4.00V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents