Smeg HTY511DSH Original Instructions Manual page 21

Table of Contents

Advertisement

Regeneration frequency setup (models with softener)
 (Default value: H03; modify the parameter to suit the mains water hardness.
 At first use, the salt tank has to be filled. It is subsequently sufficient simply to fill up with
regenerating salt when necessary.
Important:
During normal operation, the dishwasher will perform a
number of washing cycles while regeneration is in
progress. During this time (5-6 cycles) the intake water
will not be treated, but this will not affect the washing
quality.
With values over 60°f an external water treatment device must be used and the regeneration frequency
must be set on H00.
Extra rinse
"Clean water" cycle
Ppm-
mg/l
150
200
300
400
500
600
Rinsing is 10" longer than the standard in each washing
On: enabled – OFF: disabled.
With this option clean water is used for every washing. At
each cycle, the washing water is completely drained and it is
replaced with clean water from rinsing.
On: enabled – OFF: disabled.
N.B.: prolonged use of this option leads to higher detergent
and rinse aid consumption.
21
Hardness
Hardness
(°dH
(°dF
German
French
degrees)
degrees)
Regeneration off
8,5
15
11
20
17
30
22,5
40
28
50
33,5
60
cycle.
Setting level
H00
H01
H02
H03
H04
H05
H06

Advertisement