Introduction

Preventive Maintenance

The following system checks should be made every six to twelve months:
• Check the Standing Wave Ratio (SWR).
• Inspect the tightness of all electrical connections.
• Inspect the antenna coaxial cable for wear or breaks on the shielding.
• Inspect the tightness of all screws and other mounting hardware.

Troubleshooting

Should the unit malfunction or perform poorly, follow these procedures:
If the transceiver is completely inoperative: Check the power cord and
fuse. If there is trouble with receiving: Check the VOLUME control setting.
Be sure the SQUELCH is adjusted properly. Possibly the radio is over-
squelched.
If there is trouble with transmitting: Check that the transmission line
(coaxial cable) is securely connected to the ANTENNA connector. Check
that the antenna is fully extended for proper operation. Check that all
transmission line (coaxial cable) connections are secure and free of
corrosion.
Blackening may occur on the Liquid Crystal Display if
the UHF CB Radio has been subjected to extreme high
temperature (above 60°C). This is not a fault. Normal LCD
operation resumes when the temperature stabilizes back to
NOTE
standard operating condition (0-55°C).