NAPCO LIBRA-P432EX Series Programming Instructions Manual page 37

Control panel/communicator
Table of Contents

Advertisement

Table 1
DATA ENTRY
RELAY #
Left
Right
Nibble
Nibble
blank (•)
blank (•)
NONE
blank (•)
1
1
blank (•)
2
2
blank (•)
3
3
blank (•)
4
4
blank (•)
5
5
blank (•)
6
6
blank (•)
7
7
blank (•)
8
8
blank (•)
9
9
blank (•)
0
10
blank (•)
B
11
blank (•)
C
12
blank (•)
D
13
blank (•)
E
14
blank (•)
F
15
1
blank (•)
16
Table 4
EVENT ID CODES
DATA ENTRIES
OPTION
LEFT
RIGHT
blank (•)
blank (•)
Area 1 Arm
blank (•)
1
Area 2 Arm
blank (•)
2
Area 3 Arm
blank (•)
3
Area 4 Arm
blank (•)
8
Zone 1
blank (•)
9
Zone 2
blank (•)
0
Zone 3
blank (•)
B
Zone 4
blank (•)
C
Zone 5
blank (•)
D
Zone 6
blank (•)
E
Zone 7
blank (•)
F
Zone 8
1
blank (•)
Zone 9
1
1
Zone 10
1
2
Zone 11
1
3
Zone 12
1
4
Zone 13
1
5
Zone 14
1
6
Zone 15
1
7
Zone 16
1
8
Zone 17
1
9
Zone 18
1
0
Zone 19
1
B
Zone 20
1
C
Zone 21
1
D
Zone 22
1
E
Zone 23
1
F
Zone 24
2
blank (•)
Zone 25
2
1
Zone 26
2
2
Zone 27
2
3
Zone 28
2
4
Zone 29
2
5
Zone 30
2
6
Zone 31
2
7
Zone 32
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
NAPCO Security Systems
RELAY EVENT OPTIONS
RELAY #
AREA
See
See
Table 1 below
Table 2 below
(right nibble)
Table 2
DATA
TURN OFF ON AREA
ENTRY
DISARM
blank (•)
NONE
1
Area 1
2
Area 2
3
Area 1 & Area 2
4
Area 3
5
Area 1 & Area 3
6
Area 2 & Area 3
7
Areas 1, 2 & 3
8
Area 4
9
Area 1 & Area 4
0
Area 2 & Area 4
B
Areas 1, 2 & 4
C
Areas 3 & 4
D
Areas 1, 3 & 4
E
Areas 2, 3 & 4
F
Areas 1-4
Table 4 (cont'd)
EVENT ID CODES
DATA ENTRIES
LEFT
RIGHT
6
8
Area 1 KP Ambush
6
9
Area 1 KP Panic
6
0
Area 1 KP Fire
6
B
Area 1 KP Aux
6
C
Area 1 KP Tamper
6
D
Area 1 Fail to Open
6
E
Area 1 Fail to Close
7
blank (•)
Area 2 KP Ambush
7
1
Area 2 KP Panic
7
2
Area 2 KP Fire
7
3
Area 2 KP Aux
7
4
Area 2 KP Tamper
7
5
Area 2 Fail to Open
7
6
Area 2 Fail to Close
TIMEOUT
EVENT ID
Enter a Time
See
period, in seconds
Table 4 below
or minutes
OPTION
RESERVED
DATA ENTRIES
RESERVED
LEFT
RESERVED
7
RESERVED
7
RESERVED
7
RESERVED
7
RESERVED
7
RESERVED
7
RESERVED
7
RESERVED
7
RESERVED
8
RESERVED
8
RESERVED
8
RESERVED
8
RESERVED
8
RESERVED
8
RESERVED
0
RESERVED
0
RESERVED
0
RESERVED
0
RESERVED
0
RESERVED
0
RESERVED
B
RESERVED
B
RESERVED
B
RESERVED
C
RESERVED
C
C
C
D
D
D
D
D
D
D
D
F
F
F
F
F
F
LIBRA LIB-P432EX Series Programming Instructions
COND.
See
Tables 5A & 5B
below
Table 5A
RELAY EVENT
ALARM TYPE OPTIONS
LEFT DATA
ALARM TYPE
TIMEOUT TYPE
ENTRIES
blank (•)
Burglary
1
Fire
4
Day Zone
8
Burglary
9
Fire
C
Day Zone
Table 5B
RELAY EVENT ACTIVATION CONDITIONS
RIGHT DATA
OPTIONS
ENTRIES
1
Alarm
2
Restore
3
Trouble
4
Trouble Restore
5
Follow Zone
Table 4 (cont'd)
EVENT ID CODES
OPTION
RIGHT
8
Area 3 KP Ambush
9
Area 3 KP Panic
0
Area 3 KP Fire
B
Area 3 KP Aux
C
Area 3 KP Tamper
D
Area 3 Fail to Open
E
Area 3 Fail to Close
F
Area 4 KP Ambush
1
Area 4 KP Panic
2
Area 4 KP Fire
3
Area 4 KP Aux
4
Area 4 KP Tamper
5
Area 4 Fail to Open
6
Area 4 Fail to Close
8
Test Timer
B
Memory Fail
C
Low Battery
D
AC Fail
E
EZM Tamper
F
Alarm Supervisory
5
RF Receiver Trouble (Tamper/Fail)
6
Wireless TX Tamper
7
Wireless TX Trouble (LB/Supervisory)
8
Area 1 Arming AWAY
9
Area 2 Arming AWAY
0
Area 3 Arming AWAY
B
Area 4 Arming AWAY
blank (•)
Keypad Fail
1
EZM Fail
2
Quickloader Device Control
5
General System Alarm
8
Area 1 General System Alarm
9
Area 2 General System Alarm
0
Area 3 General System Alarm
B
Area 4 General System Alarm
blank (•)
Relay Control Group 1
1
Relay Control Group 2
8
Entry Relay Area 1
9
Entry Relay Area 2
0
Entry Relay Area 3
B
Entry Relay Area 4
Page 37
Minutes
Minutes
Minutes
Seconds
Seconds
Seconds

Advertisement

Table of Contents
loading