9.0 CLEANING PROCEDURES

CAUTION: Do not use cleaning agents that are corrosive.
Your kettle should be cleaned immediately after each use.
1. Ensure that steam supply is OFF.
2. Pre-rinse inside of kettle thoroughly and tilt to remove any food particles.
3. Using a nylon brush, clean kettle with a mild detergent and warm water rinse. Never use
steel wool or scouring powder as it will scratch stainless steel.
4. Tilt kettle and rinse thoroughly draining out detergent solution.
Use of cleaning agents that contain chloride, acids or salts are corrosive and may cause pitting
and corrosion when used over a period of time; this will reduce the life of the appliances.
Should pitting or corrosion occur this is not covered by warranty.
Follow the recommended cleaning instructions. Use a mild detergent, warm water and rinse
thoroughly.
WHAT TO DO IF SURFACE RUST APPEARS
Metal utensils should never be used as they will scratch the surface of the equipment and rust
may begin to form. To remove surface accumulation of rust from the inadvertent use of such
utensils, the following procedure may be used.
CAUTION: Improper use of this procedure may damage your
appliance!
1. Use undiluted white vinegar with a non-abrasive scouring pad (plastic) or cloth on the
affected area to remove the rust stain. The appliance should not be heated and remain at
room temperature during the entire cleaning process.