INSTALLATION AND OPERATION MANUAL, DIRECT STEAM KETTLES MOUNTED ON
MODELS EMT-6, EMT-10, EMT-12, EMT-6-6, EMT-10-6, EMT-10-10
EXHAUST HOOD
An exhaust system should be located directly above the boiler to exhaust steam and heat
generated by the boiler.
PLUMBING CONNECTIONS (See Page 4)
WARNING: Plumbing connections must comply with applicable sanitary,
safety, and plumbing codes.
Water Supply Connection
The incoming cold water supply connection, at the rear of the boiler cabinet, requires 3/8" tubing
and water pressure of 25 - 50 psig. A manual shut-off valve must be provided convenient to the
boiler; this valve should be open when the boiler is in operation.
Drain Connection
The boiler drain (2" IPS) should be piped to a floor drain near the boiler. There should be no
solid drain connection; an "open gap" between the boiler and the floor drain is required.
PART NUMBER 10071R2
ELECTRIC BOILER BASE CABINET,