Crown EMT-6-6 Installation & Operation Manual page 9

Direct steam kettles on electric boiler cabinet base
Hide thumbs Also See for EMT-6-6:
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL, DIRECT STEAM KETTLES MOUNTED ON
MODELS EMT-6, EMT-10, EMT-12, EMT-6-6, EMT-10-6, EMT-10-10
LEVELLING AND ANCHORING THE CABINET
1. Place appliance in the installation position.
2. Place a carpenter's level on top of the appliance and turn the adjustable feet to level side-to-
side and front-to-back.
3. Mark hole locations on the floor through the anchoring holes provided in the rear flanged
adjustable feet.
4. Remove appliance from installation position and drill holes in locations marked on the floor.
(See installation diagram on page 4.) Insert proper anchoring devices (not supplied).
5. Place appliance back in the installation position.
6. Place carpenter's level on top appliance and re-level side-to-side and front-to-back.
7. Bolt and anchor appliance securely to the floor.
8. Seal bolts and flanged feet with silastic or equivalent compound.
ELECTRICAL CONNECTIONS
WARNING: Electrical and grounding connections must comply with
the applicable portions of the National Electrical Code and/or other
local electrical codes.
WARNING: Disconnect electrical power supply and place a tag at
the disconnect switch to indicate you are working on the circuit.
When making electrical connections, use copper wire suitable for at least 200°F (90°C). The
steamer must be grounded in accordance with the National Electrical Code or applicable local
codes. The wiring diagram is located on the inside of the right panel.
PART NUMBER 10071R2
ELECTRIC BOILER BASE CABINET,
9
2005-08-08

Advertisement

Table of Contents
loading

Table of Contents