Download Print this page
ACP DEC21E2 Technical Information

ACP DEC21E2 Technical Information

International commercial microwave
Hide thumbs Also See for DEC21E2:

Advertisement

Quick Links

International Commercial Microwave
230 V, 50 Hz Models
DEC21E2
P1333123M
MCHDC521
P1333122M
• Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.
• Refer to Service Manual RS5320013 for detailed installation, operating, testing, troubleshooting, and disassembly
instructions.
All safety information must be followed as provided in Service Manual RS5320013.
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Power Source
Voltage AC
Amperage (single unit)
Frequency
Single phase, 3 wire earthed
Plug
Power Output
Nominal microwave energy (IEC705)
Minimum temperature rise (∆T)
Operating frequency
Power Consumption
Cook condition microwave
Dimensions
Cabinet
Width
Height
Depth
Oven Interior
Width
Height
Depth
Weight
Crated
July 2010
©2010 ACP, Inc.
!
!
Models
Technical Information
HDC5212
CHDC5212
CAUTION
W ARNING
MCHDC521
230 VAC
16 A
50 Hz
X
Marechal DS3
2100 Watts
21ºF/11.5ºC
2450 MHz
3000 Watts
423 mm
335 mm
578 mm
331 mm
175 mm
305 mm
31 kg
1
P1333121M
P1333126M
DEC21E2
HDC5212
CHDC5212
230 VAC
32 A
50 Hz
X
CEE 7/7 Schuko
2100 Watts
21ºF/11.5ºC
2450 MHz
3000 Watts
423 mm
335 mm
578 mm
331 mm
175 mm
305 mm
31 kg
16500017

Advertisement

loading

Summary of Contents for ACP DEC21E2

  • Page 1 423 mm Height 335 mm 335 mm Depth 578 mm 578 mm Oven Interior Width 331 mm 331 mm Height 175 mm 175 mm Depth 305 mm 305 mm Weight Crated 31 kg 31 kg July 2010 16500017 ©2010 ACP, Inc.
  • Page 2: Component Specifications

    Line to Line ............8 M Ω Line Load Load to Load........... .8 M Ω Earth Line to Load ............ Continuity. Any terminal to Earth ........Infinite. Wire Harness Test continuity of wires ........Continuity. 16500017 July 2010 ©2010 ACP, Inc.
  • Page 3 6 & 9 Continuity 5 & 9 Continuity Start 4 & 9 Continuity Stop/Reset 4 & 8 Continuity Power Level 5 & 8 Continuity 6 & 8 Continuity Time Entry 7 & 8 Continuity July 2010 16500017 ©2010 ACP, Inc.
  • Page 4 Apply power to oven with door closed. Idle Condition: Oven plugged in, display blank (no other components operating). Standby Condition: Open oven door, light and motors operate. Cook Condition: Food load in oven, cook cycle initiated. 16500017 July 2010 ©2010 ACP, Inc.
  • Page 5: Power Test

    22 ....2200 6.5 .....1200 12 ....2200 14....1400 24 ....2400 7.5 .....1400 13 ....2400 17....1700 25 ....2500 9.5 .....1700 13.5 ..2500 18....1800 27 ....2700 10 ....1800 15 ....2700 19....1900 30 ....3000 10.5 ...1900 16.5 ..3000 July 2010 16500017 ©2010 ACP, Inc.
  • Page 6: Wiring And Schematic Diagrams

    WH-1 MAGNETRON (BOTTOM) WH-28 RD-10 TERM TERM BK-25 MAG TCO PK-11 LINE LINE LINE LINE LOAD LOAD FILTER FILTER GY-19 POWER GN/YL CAPACITOR CAPACITOR TRANSFORMER (BOTTOM) (TOP) RECTIFIER RECTIFIER 13064102 DEC21E2 HDC5212 MCHDC521 CHDC5212 16500017 July 2010 ©2010 ACP, Inc.
  • Page 7 J2-2 J4-1 TRIAC POWER J2-4 CONTROL J2-5 BOARD J1-1 J1-2 INTERLOCK SWITCH (PRIMARY) POWER TRANSFORMER CAPACITOR CAPACITOR RESISTOR RESISTOR RECTIFIER MAGNETRON 1 MAGNETRON 2 (TOP) (BOTTOM) 13064102 DANGER HIGH VOLTAGE DEC21E2 HDC5212 MCHDC521 CHDC5212 July 2010 16500017 ©2010 ACP, Inc.

This manual is also suitable for: