Download Print this page

ACP DEC21E2 Technical Information page 3

International commercial microwave
Hide thumbs Also See for DEC21E2:

Advertisement

Component Specifications
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Illustration
Transformer
1
#
COM
2
#
5
#
6
#
7
#
8
#
Stirrer motor
230 VAC
Interlock switch
assembly
Primary /
Logic
Mo nitor
Secondary
Touch Panel
Assembly
July 2010
©2010 ACP, Inc.
!
WARNING
Component
Discharge Capacitor
Remove all wires from terminals, and
measure resistance from:
4
#
230 to Common ...............................................
Terminal 5 to 6 .................................................
Terminal 7 to 8 .................................................
Terminal 4 to Earth screw on transformer .......
Terminal 4 to any other terminal ......................
Remove all wires from motor.
Measure resistance across terminals ............... Approximately 23 KΩ.
Disconnect wires to switch.
With door open measure resistance from:
Terminal C to NO
Terminal C to NO
Terminal C to NC
With door closed measure resistance from:
Terminal C to NO
Terminal C to NO
Terminal C to NC
Primary / Logic C
Monitor
Secondary
Continuity is indicated as 100 Ω and below.
Pin 1: Ground.
Testing
Primary ...........................
Secondary.......................
Monitor ............................
Primary ...........................
Secondary.......................
Monitor ............................
Door Closed
NO
C
NC
C
NO
10
9
8
7
6
5
Split
4
3
2
1
3
Results
1 Ω.
<1 Ω.
<1 Ω.
38 Ω.
Infinite resistance. If not, replace
transformer.
Infinite.
Infinite.
Continuity.
Continuity.
Continuity.
Infinite.
Pad
Trace
Measurement
1
8 & 10
Continuity
2
7 & 10
Continuity
3
6 & 10
Continuity
4
5 & 10
Continuity
5
4 & 10
Continuity
6
3 & 10
Continuity
7
8 & 9
Continuity
8
7 & 9
Continuity
9
6 & 9
Continuity
0
5 & 9
Continuity
Start
4 & 9
Continuity
Stop/Reset
4 & 8
Continuity
Power Level
5 & 8
Continuity
X 2
6 & 8
Continuity
Time Entry
7 & 8
Continuity
16500017

Advertisement

loading

This manual is also suitable for:

P1333123mHdc5212P1333121mMchdc521P1333122mChdc5212 ... Show all