TRENDnet User's Guide
•
Cable diagnostic test
•
IPv6: IPv6 Static IP
Link Aggregation
•
Static link aggregation and 802.3ad dynamic LACP (Up to 4 groups)
Quality of Service (QoS)
•
802.1p Class of Service (CoS)
•
Bandwidth Control per port
•
Queue Scheduling: Strict Priority (All-High-Before-Low), Weighted Round Robin
(WRR)
VLAN
•
802.1Q Tagged VLAN
•
Asymmetric VLAN
•
Up to 16 VLAN groups, ID Range 1-4094
Multicast
•
IGMP Snooping v1, v2
Port Mirror
•
One to one
•
Many to one
Access Control
•
Loopback Detection
•
Trusted Host/IP Access List
Minimum Cable Requirements
•
10GBASE-T (10 Gbps): Cat 6 twisted pair @ 55m / 180 ft. (max.) / Cat 6a or Cat
7 twisted pair @ 100m / 328 ft. (max.)
•
™
NBASE-T
(5 Gbps): Cat 6 twisted pair @ 100m / 328 ft. (max.)
•
™
NBASE-T
(2.5 Gbps): Cat 5e twisted pair @ 100m / 328 ft. (max.)
•
1000BASE-T (1 Gbps): Cat 5e twisted pair @ 100m / 328 ft. (max.)
•
100BASE-TX (100 Mbps): Cat 5 twisted pair @ 100m / 328 ft. (max.)
© Copyright 2018 TRENDnet. All Rights Reserved.
Power
•
Input: 100 – 240V AC, 50/60Hz, internal power supply
•
Output: 12V DC, 3.5A
•
Max. Consumption: 28.5W
Smart Fan / Acoustics
•
Quantity: 2
•
Noise Level: 39.5 dBA (max.)
MTBF
•
207,390 hours
Operating Temperature
•
0° – 50° C (32° – 122° F)
Operating Humidity
•
Max. 90% non-condensing
Dimensions
•
330 x 230 x 44mm (13 x 9 x 1.73 in.)
•
Rack mountable 1U height
Weight
•
2.31kg (5.01 lbs.)
Certifications
•
CE
•
FCC
Warranty
•
Lifetime
TEG-7080ES