Summary of Contents for SRS Lighting iGENT-G2
Page 1
DMX/RS232 Converter Instruction Manual Models: iGENT-G2-5 version 1.0 since 4 June 2020 ATTENTION! This instruction manual contains important information about the installation and the use of the equipment. Please read and follow these instructions carefully. Always ensure that the power to the equipment is disconnected before opening the equipment or commencing any maintenance work.
IMPORTANT SAFETY INFORMATION The following general safety precautions have to be observed during all phases of operation, service, and the repair of this equipment. Failure to comply with these precautions or with specific warnings in this manual violates safety standards of design, manufacture, and the intended use of this equipment.
Rear panel: Function description iGENT-G2 is a device that functions as a multifunction converter from DMX to RS232 commands. The main feature is easy control user interface which helps to create and program new commands into the device. iGENT-G2 was originally developed to control the DMX projectors, Plasma TV displays and other equipment with RS232 or RS422 port.
Page 4
Please install the iGENT-G2 application. Please start the iGENT-G2 application Click File New project and name it: Then save it on local disk: ( 4 / 12)
Page 5
Please use mouse and make right click in My Project window. There will be displayed window with device manufacturer name: You will see new manufacturer folder there. Here you can add various device per same manufacturer. With right click on New Manufacturer you can add new device and setup communication parameters ( 5 / 12)
Page 6
Error reply: when this or no reply is received – unit will retry to send the command Wait time: specify time that iGENT-G2 will wait for Normal reply/Error reply Retry count: specifies how many times the iGENT-G2 will resend the RS232 command when Normal reply has been not received.
Page 7
Now please click by right button of mouse inside DMX window. Next dialog will be displayed is DMX channel which trigger the command DMX: Low / High value: 1-512 – command will be sent when there is DMX value of 1-521 128-512 : command will be sent when DMX value is greater than 50% RS232 command: This will be sent out from RS232/RS422 –...
Page 8
How to save the config file of iGENT-G2: Please click to iGENT-G2 HW>SAVE. Now your file that will be sent via USB is saved on local disk. How to send config file to HW of iGENT-G2: Click iGENT-G2 HW> SEND iGENT-G2 and select file /with.bin/ you like to send to the...
Page 9
Click OPEN and file will be sent via USB. If there is no USB connected or there is no power on iGENT-G2 this dialog will be displayed: Then reconnect power, check POWER led and USB cable connected to computer. iGENT-G2 firmware update...
Page 10
Click OPEN and in bottom corner select Firmware files Firmware files will be displayed. Please select iGENT-G2_ver.1.4.fw and click OPEN ( 10 / 12)
Page 11
Firmware files will be displayed. Please select iGENT-G2_ver.1.4.fw and click OPEN. You will see the firmware file link in File: Now press Send: You will see progress bar and the information window will be displayed. ( 11 / 12)
According to guidelines 89/336 EEC and 92/31 EEC: Name of producer: SRS Group s.r.o. Address of producer: Rybnicna 36/D, SK- 83106 Bratislava, Slovak Republic Declares that the product Name of product: iGENT-G2 converter Type: iGENT-G2, iGENT-G2-DIN Corresponds to the following product specifications: Safety: EN60065, resp. EN 60950 EMC: EN55103-1, resp.