Wiring Terminal List - ASA Electronics IN-COMMAND JRVCS105 Installation And Operation Manual

Rv control and monitoring system
Hide thumbs Also See for IN-COMMAND JRVCS105:
Table of Contents

Advertisement

WIRING TERMINAL LIST

The wiring diagram depicts all the wiring connections required for proper operation of the unit.
The TX (transmit) and RX (receive) wires from the BCM to DC are reversed at each device (the BCM transmits and the DC receives, and vice versa).
BODY CONTROL MODULE (BCM) CONNECTIONS
PIN NO.
WIRE GAUGE
DESCRIPTION
1
18 AWG
FRESH TANK 1
2
18 AWG
BLACK TANK 1
3
18 AWG
BLACK TANK 2
4
18 AWG
GRAY TANK 1
5
18 AWG
GRAY TANK 2
6
18 AWG
GRAY TANK 3
7
18 AWG
TANK COMMON 7V
8
14 AWG
LIGHT GROUPS +12V (IN)
9
14 AWG
LIGHT GROUP 1 – 12V (GND)
10
14 AWG
LIGHT GROUP 1 +12V (OUT)
11
14 AWG
LIGHT GROUP 2 -12V (GND)
12
14 AWG
LIGHT GROUP 2 +12V (OUT)
13
14 AWG
AWNING LIGHT -12V
14
14 AWG
AWNING LIGHT +12V (OUT)
15
18 AWG
WATER HEATER FAULT
16
18 AWG
WATER HEATER GROUND
17
18 AWG
WATER HEATER ON
18
18 AWG
WATER HEATER ON (ELECTRIC)
PIN NO. WIRE GAUGE
DESCRIPTION
(IN)
19
16 AWG
TRAVEL LOCK +12V
(IN)
20
14 AWG
WATER PUMP +12V
(IN)
21
14 AWG
WATER PUMP -12V
(IN)
22
14 AWG
WATER PUMP +12V
(IN)
23
12 AWG
MOTOR 5 -12V
(IN)
24
12 AWG
MOTOR 5 +12V
(OUT)
25
10 AWG
MOTOR 4 -12V
26
10 AWG
MOTOR 4 +12V
27
10 AWG
MOTOR 3 -12V
28
10 AWG
MOTOR 3 +12V
29
10AWG
MOTOR 2 -12V
30
10 AWG
MOTOR 2 +12V
(GND)
31
10 AWG
MOTOR 1 -12V
32
10 AWG
MOTOR 1 +12V
33
10 AWG
CHASSIS GROUND
34
10 AWG
MOTOR FEED+12V
(GAS)
35
10 AWG
BCM +12V
36
N/A
NONE
(IN)
(OUT)
(GND)
(IN)
(IN)
(OUT)
(IN)
(OUT)
(IN)
(OUT)
(IN)
(OUT)
(IN)
(OUT)
(IN)
(IN)
(IN)
6