Setting Logging Conditions; Logging Only At An Ng/Only At An Ok; Logging By All Conditions - Omron ZG2-DSU11 User Manual

Smart sensor data storage unit
Table of Contents

Advertisement

Setting Logging Conditions

Set which data is to be logged. You can select from the following five logging conditions.
• Only at an NG/only at an OK
• All conditions
• At a fixed cycle
• At individual fixed counts
• At a logging cycle specified by an external signal

Logging Only at an NG/Only at an OK

Set logging according to the judgment result of a specific Sensor Controller.
FUN mode-[SOURCE]-[LOGGING]-[MEAS]
Setting value
CH
JUDGE

Logging by All Conditions

Logging is performed by all conditions regardless of judgment result.
FUN mode-[SOURCE]-[LOGGING]-[MEAS]
Setting value
CH
JUDGE
32
Setting Logging Conditions
Description
Selects the channel of the Sensor Controller whose judgment result
is to be monitored.
NG+ERROR: Logging is performed only when the overall judgment
of the CH currently being monitored is NG and ERROR.
NG: Logging is performed only when the overall judgment of the
CH currently being monitored is NG.
PASS: Logging is performed only when the overall judgment of the
CH currently being monitored is PASS (OK). (default value)
Description
Select the channel of the connected Sensor Controller. When two
Controllers are connected, either Sensor Controller may be
selected.
Select [All].
ZG2-DSU User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zg2-dsuZg2-dsu41257553

Table of Contents