Possible Number of Logging Data

Possible Number of Logs to Internal Memory
Logged Data
Measurement values only
Profiles only
Both measurement values and profiles
*1 Logging is possible up to 65,000 times regardless of the number of connected Sensor
Controllers and number of preset tasks. When the number of saves reaches 65,000
times, logged data is overwritten starting with the oldest data.
*2 When the number of saves reaches 5,120 times, logged data is overwritten starting
with the oldest data.
Possible Number of Saves to Memory Card
When logging ends, logged data is saved to Memory Card as a single file.
The possible number of saves differs according to the amount of remaining space on the
Memory Card, number of connected Sensor Controllers and the number of preset tasks.
Refer to the following table.
Logged Data
Measurement values only
Profiles only
Both measurement values and
profiles (1 channel)
Important
The numerical values in the table above are provided for reference only. Please note that the
number of saves may fluctuate depending on the setup status even with the same number of
channels or tasks.
28
How Logging Works
Number of Saves to Internal Memory
Max. 65,000 times (*1)
Max. 5,120 times (*2)
Max. total 5,120 times (*2)
Setting
Number of Saves to 256 MB
Memory Card
2 CH x 8 tasks
Max. 1.3 million times
(65,000 times x 20 files)
1 CH x 1 task
Max. 7.15 million times
(65,000 times x 110 files)
1 CH only
Max. 35,328 times
(256 times x 138 files)
-
Max. total 30,720 times (256 times x
120 files) regardless of preset number
of tasks