SLOT

SLOT MENU
ACTIVE SLOT
1
OPTION*
POWER CONTROL
POWER SUPPLY
POWER BUTTON
FORCE SHUTDOWN
RESET
3
Connection Status*
Power Status*
3
3
Module*
POWER SETTING
AUTO POWER UP
AUTO SHUTDOWN*
POWER SUPPLY OFF
DELAY
AUTO DISPLAY OFF
OFF WARNING
COMPUTE MODULE
POWER CONTROL
POWER SUPPLY
POWER BUTTON
RESET
Connection Status
Power Status
Module
Sets the active Option Board slot.

NOTE:
Only the selected input will work.
Configure settings for a connected Option Board.
Controls power to an Option Board.
Select [ON] then press SET on the remote control to power on the device.
Select [OFF] then press SET on the remote control to power off the device.

NOTE:
The option that is highlighted under [POWER SUPPLY] when you open the [POWER CONTROL]
menu indicates the current power status. If [YES] is highlighted, the power is on. If [NO] is
highlighted, the power is off.
Allows the same operation as the power button on the installed Option Board.
Press [YES] to force a shutdown of the installed Option Board.

NOTE:
Please use this function only when the operating system cannot be shut down manually.
Press [YES] to force a shutdown and restart of the Option Board when it does not respond to shutdown
using the [POWER BUTTON] or [FORCE SHUTDOWN] function.

NOTE:
This function may corrupt data files on the Option Board or data files on a storage device
connected to an installed Option Board.
Please only use this function when [POWER BUTTON] and [FORCE SHUTDOWN] cannot be
carried out.
Shows the connection status of an Option Board. If the status is not "Connected" then a device is not
installed.
Shows the operating status of the installed Option Board.
Shows information about the installed Option Board.
The installed Option Board will be turned on automatically when the monitor power is turned on.
2,
*
4
The installed Option Board is turned off when the monitor is switched into standby mode.
When [OFF] is selected at [SLOT POWER], this sets the time delay after [AUTO SHUTDOWN] is executed
until the power to the Option Board is turned off.
Allows to the monitor switch into the same status when the installed device goes into standby or power
save mode.
Shows a warning, when shutting down the power to the Option Board, that the device should be turned off
from within the OS of the device. This message cannot be changed.
This function is available when [POWER SUPPLY] is [OFF].
Configure settings for a Raspberry Pi Compute Module Interface Board and Raspberry Pi Compute
Module.
Controls power to the Compute Module.
Select [ON] then press SET on the remote control to power on the device.
Select [OFF] then press SET on the remote control to power off the device.

NOTE:
The option that is highlighted under [POWER SUPPLY] when you open the [POWER CONTROL]
menu indicates the current power status. If [YES] is highlighted, the power is on. If [NO] is
highlighted, the power is off.
Performs a normal shut down of the Compute Module.
Press [YES] to force a shutdown and restart of the Compute Module when it does not respond to
shutdown using the [POWER BUTTON] function.

NOTE:
Press SET to force a shutdown and restart of the Compute Module when it does not respond to
shutdown using the [POWER BUTTON] function.
Shows the connection status of a Compute Module. If the status is not "Connected" then a device is not
installed.
Shows the operating status of the Compute Module.
Shows information about the Compute Module Interface Board.
English−83