TOOL
1. Clean the teeth on the feedwheel and the gripper plug with the special brush provided.
3. Periodically clean the tool with compressed air.
4. Disassemble, clean and lubricate the welding mechanism.
GEAR HOUSING
Periodically check the gear housing portion of the tool:
1. Remove the end cap from the front of the gear housing by removing the set screw and pulling
the end cap off.
2. Check for adequate lubrication and wear of the Spiroid worm gear and ring gear.
3. This portion of the tool should be one-third full of gear grease.
4. Reinstall the end cap.