Installer Section; Alarm Removal - Ei Electronics Ei161e Instruction Manual

230v smoke & heat alarms with rechargeable battery backup
Hide thumbs Also See for Ei161e:
Table of Contents

Advertisement

1
LOCATE CORRECT SITING POINT
ALARM SHOULD BE CEILING MOUNTED AT LEAST 300mm FROM
WALLS & OBSTRUCTIONS, IDEALLY CENTRALLY IN ROOM/AREA
2
FIX & WIRE BASEPLATE
WIRE TO TERMINALS ON THE BASEPLATE AND FIX BASEPLATE
TO CEILING USING THE FIXINGS PROVIDED
3
SLIDE ON ALARM
SLIDE ALARM ONTO BASEPLATE. A CLICK SHOULD BE HEARD
AS THE TAMPER-PROOF CATCH ENGAGES
4
TEST ALARMS
PRESS AND HOLD THE TEST BUTTON ON THE ALARM. THE
ALARM AND ANY OTHER INTERCONNECTED UNITS SHOULD SOUND
1
LOCATE REMOVAL SLOT & INSERT SCREWDRIVER
LOCATE THE ARROW ON THE FRONT FACE OF THE ALARM
THE SLOT IS LOCATED DIRECTLY ABOVE THE ARROW
INSERT A FLAT-BLADED SCREWDRIVER HORIZONTALLY
APPROX. 1cm INTO THE CENTRE OF THE REMOVAL SLOT
2
SLIDE ALARM OFF BASE & REMOVE ALARM
WITH THE SCREWDRIVER STILL INSERTED, PUSH THE LOWER
HALF OF THE ALARM AWAY FROM THE SCREWDRIVER, IN THE
DIRECTION OF THE ARROW ON THE COVER
WITH THE SCREWDRIVER STILL INSERTED, PUSH THE LOWER
HALF OF THE ALARM AWAY FROM THE SCREWDRIVER, IN THE
DIRECTION OF THE ARROW ON THE COVER

Installer Section

Installation Guide

Alarm Removal

9