USER GUIDE
GENERAL BOARD FUNCTIONS
ON/OFF
Light
Change F/C
Showroom Mode
Sabbath Mode
Service Mode
3 Hour Shutoff Mode
(Silent Mode)
Clean Mode
PROGRAM AN UNPROGRAMMED BOARD
1.
Plug the unit into appropriate power source as defined
on the data plate.
2.
Once the double dashes appear, hold the hidden
U-Line button for 3-5 seconds.
3.
When 00 appears, use the up and down buttons to
select the appropriate model number.
4.
Press the light bulb button once.
5.
The display will blink, and then will appear as the
programmed display.
To set a programmed board to the correct model, see
"Programming the Unit to Correct Model Number" in
the "Control Operation-Service" section.
Quick Guide
Press power button and unit will turn on or off.
Hold the Down key and Light key. Adjust between settings 0, 1, or 2. Tap Light key to save.
Hold Up and Down buttons for 5 seconds.
Hold Light and Power buttons for 5 seconds to enter. Unplug to exit. The degree symbol will flash
while in Showroom mode.
Hold Light button for 5 seconds to enter. Tap Light button to exit.
Hold down Hidden button (U-Line logo) to enter. Scroll through options with Up and Down buttons.
Hold Down button and Power button for 5 seconds to enter Silent Mode on select models.
Hold the Clean button for 5 seconds to enter Clean mode on select models.
THERMISTOR RESISTANCE DATA
TEMP (F)
TEMP (C)
-40
-40
-31
-35
-22
-30
-13
-25
-4
-20
5
-15
14
-10
23
-5
32
0
41
5
50
10
59
15
68
20
77
25
86
30
95
35
104
40
113
45
122
50
131
55
140
60
149
65
158
70
167
75
176
80
* + 5%
28
u-line.com
Nominal
Resistance
(OHMS)*
169157
121795
88766
65333
48614
36503
27681
21166
16330
12696
9951
7855
6246
5000
4029
3266
2665
2186
1803
1495
1247
1044
879
743
631