U-Line ADA Series User Manual & Service Manual
U-Line ADA Series User Manual & Service Manual

U-Line ADA Series User Manual & Service Manual

Clear ice machine with pump
Hide thumbs Also See for ADA Series:

Advertisement

Quick Links

USER GUIDE & SERVICE MANUAL
ADA Series
UACP115
15" Clear Ice Machine with Pump

Advertisement

Table of Contents
loading

Summary of Contents for U-Line ADA Series

  • Page 1 USER GUIDE & SERVICE MANUAL ADA Series UACP115 15” Clear Ice Machine with Pump ● ●...
  • Page 2 USER GUIDE & SERVICE MANUAL u-line.com Table of Contents Intro Parts Ordering Replacement Parts Safety R600a Specifications Safety and Warning System Diagnosis Guide Disposal And Recycling Compressor Specifications Control Operation - Service Installation Thermistor Environmental Requirements Warranty Electrical Cutout & Product Dimensions...
  • Page 3: Product Information

    ® to preserve the right product, in the right place, at the right temperature. Since 2014, U-Line has been part of the Middleby family of brands. All products are designed, engineered, and assembled in Milwaukee, Wisconsin, USA, and select products are available worldwide.
  • Page 4: Safety And Warning

    USER GUIDE u-line.com Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
  • Page 5: Disposal And Recycling

    USER GUIDE u-line.com Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal,...
  • Page 6: Environmental Requirements

    USER GUIDE u-line.com Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce...
  • Page 7 USER GUIDE u-line.com Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • Page 8: Cutout & Product Dimensions

    14 ⁄ ” (378 mm Cutout & Product Dimensions PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or 28” (711 mm) rear.
  • Page 9: Side-By-Side Installation

    USER GUIDE u-line.com Side-by-Side Installation Hinge-by-Hinge Installation (Mullion) When installing two units hinge-by-hinge, 13/16” (22 mm) OTHER SITE REQUIREMENTS is required for integrated models. Additional space may be needed for any knobs, pulls or handles installed. Side-by-Side Installation ⁄ ” (22 mm Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s...
  • Page 10: Water Hookup

    USER GUIDE u-line.com Water Hookup WATER SUPPLY CAUTION Observe and follow all local building codes when installing this appliance. This ice machine must be connected to a potable cold water supply line. delivering water pressure between a minimum of 20 psi and a maximum of 120 psi.
  • Page 11: Drain Connection

    USER GUIDE u-line.com Drain Air Gap (Optional Hook-Up) DRAIN CONNECTION CAUTION The floor drain must be large enough to Waste accommodate drainage from all attached drains. Follow these guidelines when installing drain Cold Water lines to prevent water from flowing back into Water Shut-Off...
  • Page 12: General Installation

    USER GUIDE u-line.com General Installation INSTALLATION Plug in the power/electrical cord. LEVELING INFORMATION Gently push the unit into position. Be careful not Use a level to to entangle the cord or water and drain lines, if confirm the unit is applicable.
  • Page 13: Grille Installation

    USER GUIDE u-line.com Grille Installation REMOVING AND INSTALLING GRILLE WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. WARNING Do NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.
  • Page 14: Door Swing

    USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Door Swing Wall Wall 1/4" Min. 2-1/8" Min. (6 mm) (54 mm) Door Swing Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets.
  • Page 15: Door Adjustments

    USER GUIDE u-line.com Door Adjustments With a Phillips screwdriver, remove the bushing screw and hing pin from the bottom hinge. REVERSING THE DOOR Location of the unit may make it desirable to mount the Closer door on the opposite side of the cabinet.
  • Page 16 USER GUIDE u-line.com Using a Phillips screwdriver, remove the toe kick from the door and attach it to the opposite side. Toe Kick Reversal Reinstall the door. Door Adjustments...
  • Page 17: First Use

    Initial startup requires no adjustments. See CONTROL OPERATION section for more details. NOTICE U-Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line.
  • Page 18: Control Operation

    USER GUIDE u-line.com Control Operation Electronic Control Control Function Guide Function Command Notes ON/OFF Press and release. Unit will immediately turn ON or OFF. The o F / o C symbol will flash briefly after 5 seconds. Interior Enable Sabbath Mode Press and hold for 5 seconds and release.
  • Page 19: Ice Production

    USER GUIDE u-line.com Evaporator Front Grid Panel Cutter Your ice machine is unique in how it forms ice with fractional freezing to form a slab of ice that is clear and has less dissolved solids than the water from which it is produced.
  • Page 20: Cleaning Condenser

    USER GUIDE u-line.com Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary.
  • Page 21: Extended Non-Use

    If the unit will be exposed to temperatures of 40 F (5 C) or less, the steps above must be followed. For questions regarding winterization, please call U-Line at 414.354.0300. CAUTION Damage caused by freezing temperatures is not covered by the warranty. Extended Non-Use...
  • Page 22: Before Calling For Service

    Find a Servicer page to locate a U-Line Authorized servicer. If your product is in Troubleshooting - What to check when problems occur: warranty please make sure to register it at www.U-Line.com/u-lineregistration.
  • Page 23: Product Liability

    The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
  • Page 24: Warranty Claims

    Claims must be submitted online at • Final billing - Remodel www.U-LineService.com Warranty parts will be shipped at no charge after U-Line • 60 day submittal deadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part description.
  • Page 25: Service Parts List

    Service Parts List USER GUIDE u-line.com u-line.com Parts UACP115-SS01A ITEM DESCRIPTION MARVEL P/N CONDENSER ASSEMBLY S41013912 MAIN CONTROL BOARD KIT 90-54002-54 GRILLE S41015692-BLK LED LIGHT WHITE S68100 ROCKER SWITCH 42246922 THERMISTOR ASSEMBLY S68092 UI DISPLAY KIT 90-54005-00 ACCESS COVER S41014463-BLK...
  • Page 26: Ordering Replacement Parts

    Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
  • Page 27 Never use a torch on a fully charged refrigeration system. Never substitute U-Line OEM replacement parts or methods of construction. R-600a must be stored and transported in Technician must observe all federal, state and local laws regarding refrigerants.
  • Page 28 USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A SPECIFICATIONS/LABELING WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians permitted to service R-600a equipped products.
  • Page 29: Leak Detection

    USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed.
  • Page 30 USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure).
  • Page 31: System Diagnosis Guide

    USER GUIDE u-line.com System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold...
  • Page 32 USER GUIDE u-line.com Compressor Specifications...
  • Page 33: Function Command

    USER GUIDE u-line.com Control Operation-Service CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY/OPTIONS UI BUTTON LAYOUT and release Unit will immediately Press ON/OFF turn ON or OFF See “Cleaning” Clean Mode section See “Sabboth Mode” Sabboth Mode section Showroom Mode 1. Hidden Button This mode is designed to show units in a display •...
  • Page 34 USER GUIDE u-line.com Thermistor Thermistor Resistance Data Nominal Resistance Thermistors are used for various temperature readings. Temp (F) Temp (C) (OHMS)* Thermistors provide reliable temperature readings using a 169157 resistance which varies based on surrounding temperatures. 121795 If a faulty thermistor is suspected, it may be tested using 88766 an accurate ohmmeter.
  • Page 35 For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.

This manual is also suitable for:

Uacp115