Page 1
USER GUIDE & SERVICE MANUAL Model: UACP115-SS01A...
Page 2
USER GUIDE & SERVICE MANUAL u-line.com Table of Contents Intro Wire Diagram Product Liability Safety Warranty Claims Safety and Warning Parts Disposal And Recycling Ordering Replacement Parts R600a Specifications Installation System Diagnosis Guide Environmental Requirements Compressor Specifications Electrical Control Operation - Service Cutout &...
U-Line Customer Care must be contacted immediately at +1.414.354.0300. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
USER GUIDE u-line.com Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
USER GUIDE u-line.com Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal,...
USER GUIDE u-line.com Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce...
Page 7
USER GUIDE u-line.com Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
14 ⁄ ” (378 mm Cutout & Product Dimensions PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or 28” (711 mm) rear.
USER GUIDE u-line.com Side-by-Side Installation Hinge-by-Hinge Installation (Mullion) When installing two units hinge-by-hinge, 13/16” (22 mm) OTHER SITE REQUIREMENTS is required for integrated models. Additional space may be needed for any knobs, pulls or handles installed. Side-by-Side Installation ⁄ ” (22 mm Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s...
USER GUIDE u-line.com Water Hookup WATER SUPPLY CAUTION Observe and follow all local building codes when installing this appliance. This ice machine must be connected to a potable cold water supply line. delivering water pressure between a minimum of 20 psi and a maximum of 120 psi.
USER GUIDE u-line.com Drain Air Gap (Optional Hook-Up) DRAIN CONNECTION CAUTION The floor drain must be large enough to Waste accommodate drainage from all attached drains. Follow these guidelines when installing drain Cold Water lines to prevent water from flowing back into Water Shut-Off...
USER GUIDE u-line.com General Installation INSTALLATION Plug in the power/electrical cord. LEVELING INFORMATION Gently push the unit into position. Be careful not Use a level to to entangle the cord or water and drain lines, if confirm the unit is applicable.
USER GUIDE u-line.com Grille Installation REMOVING AND INSTALLING GRILLE WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. WARNING Do NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.
USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Door Swing Wall Wall 1/4" Min. 2-1/8" Min. (6 mm) (54 mm) Door Swing Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets.
USER GUIDE u-line.com Door Adjustments With a Phillips screwdriver, remove the bushing screw and hing pin from the bottom hinge. REVERSING THE DOOR Location of the unit may make it desirable to mount the Closer door on the opposite side of the cabinet.
Page 16
USER GUIDE u-line.com Using a Phillips screwdriver, remove the toe kick from the door and attach it to the opposite side. Toe Kick Reversal Reinstall the door. Door Adjustments...
Initial startup requires no adjustments. See CONTROL OPERATION section for more details. NOTICE U-Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line.
USER GUIDE u-line.com Control Operation Electronic Control Control Function Guide Function Command Notes ON/OFF Press and release. Unit will immediately turn ON or OFF. The o F / o C symbol will flash briefly after 5 seconds. Interior Enable Sabbath Mode Press and hold for 5 seconds and release.
USER GUIDE u-line.com Evaporator Front Grid Panel Cutter Your ice machine is unique in how it forms ice with fractional freezing to form a slab of ice that is clear and has less dissolved solids than the water from which it is produced.
USER GUIDE u-line.com Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit will not perform as expected. Do not install the unit behind a door.
Page 21
“nickel safe” ice maker cleaner. CAUTION CAUTION Use only U-Line-approved ice machine cleaner Forcing ice through the grid cutter will break the and follow all label warnings and directions. grid cutter wires. Incorrect chemical usage, and any damage that may result, is not covered by warranty.
Page 22
USER GUIDE u-line.com Replace the splash shield if removed. After the cleaning cycle is completed, verify that all build-up has been removed. If not, repeat the clean cycle procedure. Pour cleaning solution slowly onto Evaporator the front edge of evaporator plate plate behind the grid cutter.
USER GUIDE u-line.com Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary.
USER GUIDE u-line.com Extended Non-Use If the ice machine is moved, not used for an extended period of time, or will be in an area that will be near freezing temperatures, it is necessary to remove any remaining water in the ice-making system.
Page 25
USER GUIDE u-line.com Disconnect the water valve’s outlet water line to the Winterization reservoir and drain the remaining water left in the plug water line trap area. 14. Remove the top clamp from the vent tube, for easy access to the air hose.
Page 26
USER GUIDE u-line.com Drain Pump Removal Unplug the ice machine from the electrical supply and remove the rear access cover from the ice machine. Remove the front panel and the toe grille from the front of the ice machine. Remove the front and rear drain pump brackets.
USER GUIDE u-line.com u-line.com Troubleshooting The ice machine is noisy: Many sounds of an ice machine are different than your household refrigerator. This subject is discussed on page BEFORE CALLING FOR SERVICE 11, but check the following: WARNING • Do you hear water being circulated in the ice...
USER GUIDE u-line.com u-line.com ICE QUALITY TROUBLESHOOTING THE DRAIN PUMP Odor, grey color, or off taste in the ice: NOTE: • Is there mineral scale build up on the evaporator If the drain pump reservoir (not the ice machine bin) reaches overfill condition, the power to the plate? The ice machine needs cleaning.
The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
Claims must be submitted online at • Final billing - Remodel www.U-LineService.com Warranty parts will be shipped at no charge after U-Line • 60 day submittal deadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part description.
Service Parts List USER GUIDE u-line.com u-line.com Parts UACP115-SS01A ITEM DESCRIPTION MARVEL P/N CONDENSER ASSEMBLY S41013912 MAIN CONTROL BOARD KIT 90-54002-54 GRILLE S41015692-BLK LED LIGHT WHITE S68100 ROCKER SWITCH 42246922 THERMISTOR ASSEMBLY S68092 UI DISPLAY KIT 90-54005-00 ACCESS COVER S41014463-BLK...
Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
Page 34
Never use a torch on a fully charged refrigeration system. Never substitute U-Line OEM replacement parts or methods of construction. R-600a must be stored and transported in Technician must observe all federal, state and local laws regarding refrigerants.
Page 35
USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A SPECIFICATIONS/LABELING WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians permitted to service R-600a equipped products.
USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed.
Page 37
USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure).
USER GUIDE u-line.com System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold...
Page 39
USER GUIDE u-line.com FMXA9C REFRIGERANT R600A 115 VAC VOLTAGE 60 Hz FREQUENCY 5 Ohm at 77 START WINDING ° ury. RUN WINDING 7 Ohm at 77 ° erious 12 Ohm at 77 ° s unit. RUN TO START 8.0 A 2.18 A...
Page 40
USER GUIDE u-line.com Control Operation-Service CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY/OPTIONS UI BUTTON LAYOUT and release Unit will immediately Press ON/OFF turn ON or OFF See “Cleaning” Clean Mode section See “Sabboth Mode” Sabboth Mode section Showroom Mode 1. Hidden Button This mode is designed to show units in a display •...
Page 41
USER GUIDE u-line.com Thermistor Thermistor Resistance Data Nominal Resistance Thermistors are used for various temperature readings. Temp (F) Temp (C) (OHMS)* Thermistors provide reliable temperature readings using a 169157 resistance which varies based on surrounding temperatures. 121795 If a faulty thermistor is suspected, it may be tested using 88766 an accurate ohmmeter.
Page 42
For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.
Need help?
Do you have a question about the UACP115-SS01A and is the answer not in the manual?
Questions and answers