Development commands
5.5
5.5.1 Firmware and imager levels
The firmware levels identify the release and build of a unit. Send the command
this information. For example: SB 01.00.00 is a first generation LSR116.
To check the latest firmware version or to update firmware, contact support@access-is.com.
Table 6. Firmware and imager commands
Command
Description
AISXXR
Simulates read outcome.
Used in Interactive mode to
communicate to the user after the host
has checked the data.
Only applicable to Interactive mode and
Host mode.
AISIOP
Interactive mode option flag.
Only applicable to Interactive mode
(AISOMD2).
If this flag is set, then the TRIG
messages from the LSR116 are sent
only on media detect and media
removed, regardless of commands from
the host.
AISRDS
Changes the configuration back to its
default values.
values, including any values specific to
your stored configuration.
AISFWV
Returns the version of the firmware.
AIS_WA
Returns the firmware version of the
imager.
AIS_TD
Returns the timestamp of the firmware
release.
AIS_BO
Enables or disables barcode reading.
This command is stored in volatile
memory so will return to the default
setting on power cycle.
AISDLE
Include DLEs (Data Link Escape).
AISNRD
Sets a 'No Read' message, sent at
defined intervals.
232CRD
CTS is raised when a 'Good Read'
output is received.
232CTS
Hardware handshaking - requires the
CTS to be high.
Page 22 of 33
Warning: This command resets
all parameters to their default
AISFWV?
Default
Parameters/Range
0 – 'Good Read'
-
1 – 'Bad Read'
2 - Ignore (requires
version 1.0.21 of the
firmware)
0
0 - Disabled
1 - Enabled
-
1
-
-
-
-
1
-
1
0 - Off
1 - On
0
0 - Off
1 - On
0
0 - Off
1–60000 milliseconds
0
0 - Off
1 - On
0
0 - Off
1 - On
Copyright © Access-IS 2020
to obtain
Need help?
Do you have a question about the LSR110 and is the answer not in the manual?