ADDITIonAl FeATURes:

FolloW Me Feature:
• NOTE:This feature can be activated from the
remote control ONLY . The remote control acts
as a remote thermostat allowing for the precise
temperature control at its location .
• To activate the Follow Me/Temp Sensing feature,
point the remote control towards the unit and
press the Follow Me/Temp Sensing button . The
remote display is actual temperature at its loca-
tion . The remote control will send this signal to
the air conditioner every 3 minutes interval until
press the Follow Me/Temp Sensing button again .
• If the unit does not receive the Follow Me/Temp
Sensing signal during any 7 minutes interval, the
unit will beep to indicate the Follow Me/Temp
Sensing mode has ended .
Auto Restart
• If the unit breaks offunexpectedly due to the
power cut, it will restart with the previous func-
tion setting automatically when the power
resumes .
bAsIC eRRoR CoDes:
Use the following guidelines to understand and troubleshoot common error codes.
e1: Room temperature sensor error.
• Unplug the unit and plug it back in .
• If error repeats, call for service .
e2: evaporator temperature sensor error
• Unplug the unit and plug it back in .
• If error repeats, call for service .
e3: Condenser temperature sensor error
• Unplug the unit and plug it back in .
• If error repeats, call for service .
e4: Display panel communication error
• Unplug the unit and plug it back in .
• If error repeats, call for service .
P1: bottom condensation tray is full
• Connect the drain hose and drain the collected water away .
• Note that frequent draining may be required, especially in humid climates
and during seasonal weather changes .
• If protection repeats after draining, call for service .
self Protection
• After the unit has stopped, it can not restart oper-
ation for 3 minutes following shut down . This is
to protect the unit . Operation will automatically
resume after 3 minutes has elapsed .
Air flow direction adjustment
• The directional blade can be adjusted automati-
cally .
• Adjust the air flow direction automatically
• When the Power is ON, the blade opens fully .
• Press the SWING button on the panel or remote
controller to initiate the Auto swing feature .
• The blade willl swing up and down automatically .
• Press the SWING button again to block the blade
in a fixed direction .
• NOTE: Please do not adjust the blade manually .