OPERATING LIMITS
L
Cooling Maximum conditions
Outdoor temperature :
Room temperature :
L
Cooling Minimum conditions
Outdoor temperature :
Room temperature :
L
Heating Maximum conditions
Outdoor temperature :
Room temperature :
L
Heating Minimum conditions
Outdoor temperature :
Room temperature :
F-GAS Regulation (EC) No. 842/2006
Do not vent R410A into atmosphere: R410A is a
fluorinated greenhouse gas, covered by Kyoto Protocol,
with a Global Warming Potential (GWP) = 1975.
INSTALLATION INSTRUCTIONS
as it satisfies Directives:
43°C D.B.
32°C D.B. / 23°C W.B.
–15°C D.B.
10°C D.B. / 6°C W.B.
24°C D.B. / 18°C W.B.
27°C D.B.
–15°C D.B.
5°C D.B.
37.4255.030.0
- Split system air conditioner -
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Units
MTAF98R5I--
MTAFB98R5I--
MTA8F98R5I--
MTA8FB98R5I--
MTAF128R5I--
MTAFB128R5I--
MTA8F128R5I--
MTA8FB128R5I--
Power Supply:
230V / 1 / 50Hz
Tools required for installation (not supplied)
1.Standard screwdriver
2.Phillips head screwdriver
3.Knife or wire stripper
4.Tape measure
5.Level
6.Sabre saw or key hole saw
7.Hacksaw
8. Core bits ø 8
04/2008
Outdoor Units
GRF98R5I--
GR8F98R5I--
GRF128R5I--
GR8F128R5I--
19.Hammer
10.Drill
11. Tube cutter
12.Tube flaring tool
13.Torque wrench
14.Adjustable wrench
15.Reamer (for reburring)
16.Hex. key
EG
I
F
D
E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTAF98R5I Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Argo MTAF98R5I Series

  • Page 1 INSTALLATION INSTRUCTIONS - Split system air conditioner - DECLARATION OF CONFORMITY This product is marked as it satisfies Directives: – Low voltage no. 2006/95/CE. – Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC and 93/68 EEC. This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation and/or operating instructions.
  • Page 2: Special Precautions

    IMPORTANT! • Ground the unit following local electrical codes. • The Yellow/Green wire cannot be used for any connection Please read before installation different from the ground connection. • Connect all wiring tightly. Loose wiring may cause This air conditioning system meets strict safety and operating overheating at connection points and a possible fire standards.
  • Page 3: Electrical Data

    Installation site selection - Indoor unit • Select a sufficiently strong location to support the weight AVOID of the unit. • Direct sunlight. • Select a location where tubing and drain hose have the • Nearby heat sources that may affect unit performance. shortest run to the outside.
  • Page 4: Dichiarazione Di Conformità

    ISTRUZIONI DI INSTALLAZIONE - Condizionatore d’aria Split System - DICHIARAZIONE DI CONFORMITÀ Questo prodotto è marcato in quanto conforme alle Direttive: – Bassa Tensione n. 2006/95/CE . – Compatibilità Elettromagnetica n. 89/336 CEE, 92/31 CEE e 93/68 CEE. Questa dichiarazione sarà nulla nel caso di impiego diverso da quello dichiarato dal Fabbricante e/o di mancata osservanza, anche solo parziale, delle istruzioni d'installazione e/o d'uso.
  • Page 5 IMPORTANTE! • Eseguire la messa a terra dell’unità secondo le norme elettriche locali. Leggere prima di iniziare l’installazione • Il conduttore giallo/verde non può essere utilizzato per collegamenti diversi dalla messa a terra. Questo sistema di condizionamento deve seguire rigidi •...
  • Page 6: Dati Elettrici

    Scelta del luogo di installazione unità interna resistente da sostenere il peso dell’unità. EVITARE • Scegliere una posizione in modo che la distanza tra le • L’esposizione diretta al sole. due unità sia la minore possibile. • La vicinanza a fonti di calore che possono danneggiare •...
  • Page 7: Notice D'installation

    NOTICE D’INSTALLATION - Climatiseur split - DECLARATION DE CONFORMITE Ce produit est marqué puisque il est conforme aux Directives: – Basse Tension n. 2006/95/CE. – Compatibilité Electromagnétique n. 89/336 CEE, 92/31 CEE et 93/68 CEE. Cette déclaration sera nulle en cas d'une utilisation différente de celle déclarée par le Constructeur et/ou de la non- observation, même si partielle des instructions d'installation et/ou d’utilisation.
  • Page 8 IMPORTANT! • Effectuez la mise à la terre de l'appareil en respectant les réglementations électriques locales. Veuillez lire ce qui suit avant de commencer • Le câble jaune/vert ne peut en aucun cas être utilisé pour Ce système de conditionnement de l'air répond à des toute autre connexion que celle de la mise à...
  • Page 9 Choix de l'emplacement d'installation - Appareil intérieur RECHERCHEZ • Un emplacement approprié à partir duquel l'ensemble de la EVITEZ pièce peut être climatisé de manière uniforme. • L'exposition directe au soleil. • Un emplacement suffisamment solide pour supporter le poids •...
  • Page 10 INSTALLATIONSANLEITUNGEN - Zweirohrsystem-Klimaanlage - KONFORMITÄTSERKLÄRUNG Dieses Produkt ist mit -Zeichen gekennzeichnet, weil es den folgenden Richtlinien entspricht: – Niederspannungsrichtilinie 2006/95/CE . – Elektromagnetische Verträglichkeit 89/336 EWG, 92/31 EWG und 93/68 EWG. Bei falschem Einsatz des Gerätes und/oder Nichtbeachtung auch nur von Teilen der Bedienungsanleitung und der Installatinsanweisungen wird diese Erklärung ungültig.
  • Page 11: Bitte Beachten

    WICHTIG! Tod verursachen. • Erden Sie das Gerät gemäß den örtlich zutreffenden Bitte vor Arbeitsbeginn lesen Vorschriften. Diese Klimaanlage entspricht strengen Sicherheits- und • Das Gelbe/Grüne Kabel ist für die ausschließliche Betriebsnormen. Verwendung als Erdleitung. • Verbinden Sie Kabel fest miteinander. Lockere Für den Installateur oder Bediener dieser Anlage ist es Verbindungen können...
  • Page 12: Elektrische Angaben

    Wahl des Installationsortes - Innenraumgerät • Wählen Sie eine Stelle, an der der Boden das Gewicht des VERMEIDEN SIE Gerätes tragen kann. • Direkte Sonneneinstrahlung. • Wählen Sie eine Stelle, von der aus die Rohre und der • Wärmequellen in der Nähe des Gerätes, die dessen Wasserablaufschlauch den kürzesten Weg nach darußen Leistungsfähigkeit beeinflussen könnten.
  • Page 13: Instrucciones De Instalacion

    INSTRUCCIONES DE INSTALACION - Acondicionador de aire Split System - DECLARACION DE CONFORMIDAD Este Producto está marcado porque responde a las Directivas: – Baja Tensión n° 2006/95/CE. – Compatibilidad Electromagnetica n° 89/336 CEE, 92/31 CEE y 93/68 CEE. Esta declaración no tendrá efecto en sólo caso de que se haga un uso diferente al declarado por el Fabricante, y/o por el no respeto, incluso parcial, de las intrucciones de instalación y/o de uso.
  • Page 14: Precauciones Especiales

    ¡IMPORTANTE! • Realizar la puesta a tierra de la unidad siguiendo las normas eléctricas locales. Leer antes de empezar la instalación • El conductor amarillo/verde no se puede utilizar para conexiones que no sean la de tierra. Este sistema de acondicionamiento cumple medidas rígidas •...
  • Page 15: Datos Electricos

    Dónde instalar la unidad interior todos los rincones. • Controlar que el lugar de apoyo es lo suficientemente EVITAR resistente como para soportar el peso de la unidad. • La exposición directa al sol. • Elegir una posición de modo que la distancia entre las dos •...
  • Page 16 INDOOR UNIT • UNITÀ INTERNA • UNITE INTERIEURE • INNENEINHEIT • UNIDAD INTERIOR Minimum operation and maintenance area. Area minima di esercizio e manutenzione. Surface minimum de fonctionnement et d’entretien. 2000 Raumbedarf des Gerätes . Area mínima de funcionamiento y manutención. 1195 Remove the aesthetic front panel.
  • Page 17 Tubing connections from the rear. Mark the holes to be made on the wall, check the horizontal position with the level (OPTIONAL HOLES). Collegamento tubi posteriore. Evidenziare i fori da eseguire sulla parete, mettere a livello (FORI OPTIONAL). Sortie arrière des tubes. Mettre en évidence les troux à effectuer sur le mur, mettre à...
  • Page 18 The indoor unit can be installed without removing the front panel. If necessary, remove the set screws placed under the two little covers. L’unità interna può essere installata senza rimuovere il pannello frontale. Se necessario, alzare i coperchietti delle viti di fissaggio e rimuoverle. L'unité...
  • Page 19 Tubing connections on right or left side. Cut a corner of the frame. Collegamento tubi laterali. Tagliare l'angolo della copertura. Sortie latérale des tubes. Couper l’opercule correspondant. Seitliche Verrohrung. Eine Ecke (rechts oder links) schneiden. Conexión lateral de tubos. Cortar el ángulo de la tapa. The refrigerant tubes and drain hose are on the right side of the unit.
  • Page 20 Running power wires plus ground wire from indoor to outdoor unit (see tab. for size of wires). Stendere un cavo multipolare con filo di terra tra le due unità (vedere tabella per la sezione dei fili). Passer les fils electriques et un fil de terre, entre les deux unités (voir tableau pour la section des fils).
  • Page 21 LEFT REAR TUBING Hang up the unit and screw partially the screws. Insert the tubes connecting the units from the outside, then bend them right and remove the inferior removable part of the frame. In case the tubes should not be long enough for the front connection, use the supplied tubes and insulations.
  • Page 22 Predispose the terminals of the wire to connect to the terminal strip, connect them and secure the wiring with clamp provided. (See wiring diagrams). WARNING Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also exist. Therefore, be sure all wiring is tightly connected.
  • Page 23 Install the condensate drain to the outside with a positive slope, form a trap at the end if necessary. Convogliare la condensa verso l'esterno assicurando una buona pendenza. Sifonare se necessario. Diriger les condensats vers l'extérieur, en assurant une bonne pente. Faire un siphon, si nécessaire.
  • Page 24 INSTALLATION TYPES • TIPOLOGIE DI INSTALLAZIONE • TYPES DE INSTALLATION TYPE VON INSTALLATION • TIPOS DE INSTALACION FREE-STANDING INSTALLATION. Front connection, right side of indoor unit. LIBERA INSTALLAZIONE. Collegamento frontale, parte destra unità interna. INSTALLATION LIBRE. Raccordement frontal, côté droite de l’unité intérieure. FREIE INSTALLATION.
  • Page 25 OUTDOOR UNIT • UNITÀ ESTERNA • UNITE EXTERIEUR • AUßENEINHEIT • UNIDAD EXTERIOR Minimum operation and maintenance area Area minima di esercizio e manutenzione. Surface minimum de fonctionnement d’entretien. Raumbedarf des Gerätes. Area mínima de funcionamiento y manutención. Provide a solid base for outdoor unit raised from the ground level. Fix unit to base using 4 anchor bolts.
  • Page 26 Use insulated copper tube. Cut approximate 30-50 cm longer than actual min. 8 mm min. 8 mm distance between units. Utilizzare del tubo in rame isolato. Tagliare con lunghezza maggiorata di 30-50 cm oltre la distanza tra le unità. Utiliser de tube en cuivre isolé. Couper à une longueur de 30-50 cm en plus de la distance entre les unités.
  • Page 27 Tighten connections using a spanner and a torque wrench; apply specified torque (see table). Stringere le connessioni utilizzando una chiave fissa e una chiave dinamometrica; attenersi alla tabella dei valori del momento torcente. Serrer les connexions à l'aide d'une clé fixe et d'une clé dynamométrique; respercter les couples de serrage.
  • Page 28 With vacuum pump still running close the low pressure knob on valve manifold. Then stop vacuum pump. Using an hexagonal key open the service valve on small tube, then close it after 10 seconds. Check tightness of all joints using liquid soap. Con la pompa del vuoto in funzione chiudere il rubinetto del gruppo manometrico (bassa pressione).
  • Page 29 BASIC FUNCTIONS OF THE SERVICE VALVES • FUNZIONI PRINCIPALI DELLE VALVOLE • FONCTIONS DE BASE DE VANNE DE SERVICE • FUNKTION DER ABSPERRVENTILE • PRINCIPALES FUNCIONES DE LAS VALVULAS Narrow tube service Wide tube service Action valve (2-way) valve (3-way) Valve cap Shipping CLOSED...
  • Page 30 Complete insulation of refrigerant tubes; wrap with insulation tape. Fix and support tubes with brackets. Seal hole in the wall, if necessary. Completare l'isolamento, proteggere con nastratura, fissare e supportare con staffe; se necessario sigillare il foro di passaggio nel muro. Compléter l'isolation des tubes protéger avec des rubans, les fixer avec des brides;...
  • Page 31 Connecting wire A (with ground conductor): Multipolar electric wire; size and length of the suggested electric wire are showed on table “electrical data”. The wires have not to be lighter than Mod. H07RN-F (according to CEI 20-19 CENELEC HD22). Connecting wire B (SHIELDED): Bipolar electric shielded wire;...
  • Page 32 REMOTE CONTROL UNIT INSTALLATION • POSIZIONE DI INSTALLAZIONE TELECOMANDO • EMPLACEMENT DE LA COMMANDE A DISTANCE • POSITION DER FERNBEDIENUNG • POSICION DE INSTALACION DEL MANDO A DISTANCIA REMOTE CONTROL UNIT INSTALLATION To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places: •...
  • Page 33 WALL-MOUNTED POSITION • Momentarily place the remote control unit in the desired mounting position. • Verify that the remote control unit can operate from this position. • Fix the support at the wall with two screws and hang the remote control unit. POSIZIONE A PARETE •...
  • Page 34 PUMP DOWN Das bedeutet: das Kühlmittel in die Außeneinheit ohne Pump down means collecting all refrigerant gas in the Gas-Verlust zurückzugewinnen. Man benutzt es, wenn system back into the outdoor unit without losing gas. das Klimagerät in eine neue Position gestellt werden Pump down is used when the unit is to be moved of muß...
  • Page 35 Remove the valve manifold. At that time, PUMP DOWN has been completed and all refrigerant gas will have been collected in the outdoor unit. Rimuovere il gruppo manometrico. A questo punto l'operazione di PUMP DOWN è completa poiché tutto il gas refrigerante è raccolto nell'unità esterna.
  • Page 36 In order to carry on a constant improvement, our products can be modified without prior notice. Per garantire un costante miglioramento dei nostri prodotti, ci riserviamo di modificarli senza preavviso. Par souci d’amélioration constante, nos produits peuvent être modifiés sans préavis. Unsere Produkte werden laufend verbessert und können Vorankündigung abgeändert Werden.