Install Vent System - Whirlpool WETLV27FW Installation Instructions Manual

24" (61 cm) & 27" (69 cm) electric
Hide thumbs Also See for WETLV27FW:
Table of Contents

Advertisement

Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path:
Select route that will provide straightest and most direct
n
path outdoors.
Plan installation to use fewest number of elbows and turns.
n
When using elbows or making turns, allow as much room
n
as possible.
Bend vent gradually to avoid kinking.
n
Use as few 90° turns as possible.
n
Determine vent length and elbows needed for best
drying performance:
Use following "Vent System Chart" to determine type of vent
n
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specifi ed
in "Vent System Chart." Exhaust systems longer than those
specifi ed will:
Shorten life of dryer.
n
Reduce performance, resulting in longer drying times
n
and increased energy usage.
The "Vent System Chart" provides venting requirements that
will help achieve best drying performance.
Vent System Chart, 27" Models
Type
Number of
of vent
90° turns
or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
Vent System Chart, 24" Models
Type
Number of
90° turns
of vent
or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
NOTE: Side exhaust installations have a 90º turn inside the
dryer. To determine maximum exhaust length, add one 90º
turn to the chart.
28
Box/louvered
Angled
hoods
hoods
37 ft. (11.3 m)
35 ft. (10.7 m)
32 ft. (9.7 m)
27 ft. (8.2 m)
23 ft. (7.0 m)
19 ft. (5.8 m)
Box/louvered
Angled
hoods
hoods
43 ft. (13.1 m)
36 ft. (11.0 m)
33 ft. (10.1 m)
26 ft. (7.9 m)
23 ft. (7.0 m)
16 ft. (4.9 m)
Vent System Chart, 27" Long Vent
Model WETLV27FW (U.S. Only)
Type
Number of
90° turns
of vent
or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
NOTE: Side exhaust installations have a 90º turn inside the
dryer. To determine maximum exhaust length, add one 90º
turn to the chart.

Install Vent System

1.
Install exhaust hood
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
2.
Connect vent to exhaust hood
Vent must fi t inside the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using
straightest path possible. Avoid 90° turns. Use clamps to seal
all joints. Do not use duct tape, screws, or other fastening
devices that extend into interior of vent to secure vent,
because they can catch lint.
Box/louvered
Angled
hoods
hoods
127 ft. (38.7 m)
121 ft. (36.9 m)
117 ft. (35.7 m)
111 ft. (33.8 m)
107 ft. (32.6 m)
101 ft. (30.8 m)
12" min.
(305 mm)
12" min.
(305 mm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wet4027ew

Table of Contents