Electrical Requirements - Canada - Whirlpool WETLV27FW Installation Instructions Manual

24" (61 cm) & 27" (69 cm) electric
Hide thumbs Also See for WETLV27FW:
Table of Contents

Advertisement

Electrical Requirements – Canada
It is your responsibility:
To contact a qualified electrical installer.
n
To be sure that the electrical connection is adequate and in
n
conformance with Canadian Electrical Code, C22.1 – latest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4-wire, single-phase, 120/240 volt,
n
60 Hz, AC-only electrical supply on a separate 30-amp circuit,
fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch
circuit.
This dryer is equipped with a CSA
n
International Certified Power Cord
intended to be plugged into a standard
14-30R wall receptacle. The cord is 5 ft.
(1.52 m) long. Be sure wall receptacle is
within reach of dryer's final location.
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 9831317.
For further information, please reference service numbers located
in "Assistance or Service" section of your Use and Care Guide.
4-wire receptacle
(14-30R)
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wet4027ew

Table of Contents