Testing And Adjustments; Final Setup - Heath Zenith SECUR360 9301 Manual

Connected led wired security motion light
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT:
• If wall mounted, make sure the fixture is mounted with the
sensor below the lamp head.
• If eave mounted, mount the fixture with sensor facing away
from the house wall. Rotate the sensor so the controls on the
bottom of the sensor (see Figure 7) face the ground.
4. Push the plastic plug firmly into the mounting bolt hole on the
light fixture (see Figure 5).
5. Caulk around mounting plate and mounting surface with silicone
weather sealant (see Figure 6).

TESTING AND ADJUSTMENTS

CAUTION: To avoid water damage and risk of electrical
shock, motion sensor controls must be facing the ground
when installation is complete.
1. Turn on the circuit breaker and light switch.
Note: The motion sensor has a 1 minute warm up period before
it will detect motion. When first turned on wait for the red LED
indicator to start blinking slowly (1 minute).
2. Slide the sensitivity (SENS) switch to the "L" position and the
ON-TIME switch to the TEST position (see Figure 7).
3. Walk through the coverage area noting where you are when the
lights turn on. Also, the LED indicator behind the motion sen-
sor lens will glow blue when motion is detected (see Figure 8).
Note: The blue LED will turn off 30 seconds after all motion has
stopped.
4. If needed, gently grasp the motion sensor and move it from side
to side or up and down to adjust the detection zone.
5. If needed, gently grasp the lamp head and move it from side to
side or up and down to adjust the light coverage area.
IMPORTANT: All of the settings on the motion sensor are also
controlled through the SECUR360 app. However, if the light loses
wi-fi connection (the LED indicator will blink blue), the motion
sensor settings will control the light until wi-fi connection is rees-
tablished. Once the light reconnects to wi-fi, the settings in the app
will control the light.
1. Adjust the sensitivity (SENS) switch as needed ("L", "M", "H").
Sensitivity set too high may increase false triggering.
2. Set the amount of ON-TIME you want the light to stay on after
all motion has stopped (1, 5, or 20 minutes).
4

FINAL SETUP

To see operational and troubleshooting information and videos,
go to www.hzsupport.com
Figure 5
LED Indicator
Figure 6
1 MIN
5 MIN
TEST
20 MIN
ON TIME
L
M
H
SENS
Figure 7
Figure 8
210227-04

Advertisement