Important Safety Instructions When using your telephone 7.Place this telephone on a equipment, basic safety precautions stable surface. Serious damage should always be followed to and/or injury may result if the reduce the risk of fire, electric telephone falls. shock and persons including the 8.Do not cover the slots and following: openings on this telephone.
Page 4
Important Safety Instructions covered by the operating dangerous voltage points or instructions. Improper short out parts that could adjustment may require result in a risk of fire or extensive work by a electrical shock. Never spill qualified technician to liquid of any kind on the restore the telephone to telephone.
Page 5
Important Safety Instructions may explode. Check with installed using an acceptable local codes for possible method of connection. In some special disposal instructions. cases, the company’s inside wiring associated with a single ADDITIONAL SAFETY NOTES line individual service may be FOR CANADIAN USERS extended by means of a certified connector assembly (telephone...
Page 6
Important Safety Instructions CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. The Ringer Equivalent Number is an indication of the maximum number of terminals allowed to be connected to a telephone interface.
Page 7
Introducing the JV-35 Thank you for selecting the exciting new JV-35 from Ameriphone. It has been designed to meet the highest quality standards to provide you with years of convenient and trouble-free service Please read these operating instructions thoroughly before using your telephone.
Features on the JV-35 Ringer volume control switch Audio output jack AC adapter Announcement switch Tone / Pulse switch Emergency buttons Braille characters Raised letters for easy identification REDIAL button MEMORY button VOL control (volume) HOLD AMPLIFY button button TONE PROG button selector (program)
Installation B. Wall Mounting A. Desk Mounting 1. Pull the handset hook 1. Plug in the long phone out and reverse its cord. position so that the 2. Plug the handset cord hook points up. into the telephone. Fig. 4- Repositioning the hook Fig.3 - Connections and installation 2.
Installation 3. Plug in the short phone 6. Lift the handset and cord. listen for a dial tone. 4. Insert the AC Adapter 7. Your JV-35 is ready to cord into the receptacle use. on the back of the JV-35. Then plug the AC Adapter into an C.
Operating your JV-35 A. Dialing Pick up the handset and dial like any other telephone. As you dial, the numbers you Figure 8 - AMPLIFY Button are dialing will be announced (Seven, five, two, etc.) If you 2.Adjust the VOL control read Braille, you can use the to suit your hearing.
Operating your JV-35 warning printed in Braille to C. Adjusting The Tone the back of the handset (See, Diagram A). 1. When you hear a voice on the line, press the AMPLIFY button. Diagram A - JV35 handset Fig. 11- Amplify Button Note: In standard use, the 2.
Operating your JV-35 Note: When the JV-35 is on HOLD, if you pick up another phone that is on the same line, the JV-35 will automatically hang up. You Fig. 13 - Ringer Switch can continue your call on the other phone.
Operating your JV-35 G. Programming The 3. Press PROG button Emergency Buttons again. The Emergency Buttons can 4. Press one of the be programmed to dial Emergency buttons. numbers with one touch. You may wish to use these buttons for police, fire or medical response.
Operating your JV-35 H. Dialing With An Emergency 2. Enter the phone number Button as you would normally dial it. 1. Lift the handset. 2. Press one of the Emergency buttons. You will hear an announcement similar to: Fig. 20 - Entering Number “Emergency One”...
Operating your JV-35 7. To change a stored automatically dialed. number or to program another memory K. Recording Emergency button, repeat this Button Identification process from step 1. Announcements The JV-35 comes with factory J. Memory Dialing pre-recorded announcements to identify each Emergency button 1.
Page 19
Operating your JV-35 beep” sound. This 4. After three seconds confirms the JV-35 is there will be a “beep” ready to be programmed. to tell you recording has stopped. Your recording will be played back immediately so you can check it, followed by a Fig.
Operating your JV-35 position and 1. Pick up the handset your recordings will be played when you press 2. Slide the an Emergency button. ANNOUNCEMENT switch to the PROG position. You will hear “Program Mode, Program Mode” followed by a “beep- Fig.
Operating your JV-35 “Bank” for that button. different memory button. Your recording can be up to three seconds 6. Otherwise, when you long. are finished recording, hang up the handset. 7. Slide the ANNOUNCEMENT switch to the CUSTOM Fig. 26 - Memory Button position and your recordings will be 4.
Page 22
Operating your JV-35 number buttons. If you 3. Press the 1 button. choose, you can record After the “beep,” say announcements for the “One” in your own number buttons in your own voice or language. voice by following these steps. Your recording can be up to one second long.
Operating your JV-35 the rest of the number N. Selecting Number buttons. Button Announcements To hear the number button 6. When you are finished announcements that were recording, hang up the pre-recorded at the factory, handset. slide the ANNOUNCEMENT switch to PRESET. 7.
A cochlear implant adapter compatible auxiliary cable cord is available from into the Audio Output port, Ameriphone that can be then plug the other end into used to plug the JV-35 your assistive listening device. directly into a speech processor.
Page 25
Operating your JV-35 Connecting the Speech WARNING! During Processor: thunderstorms, avoid using telephones as electric shock from lightning can occur. Caution: Before plugging any cord into your speech processor, you must consult your implant manufacturer. • Plug the mono end of the plug into the speech processor.
ACTION JV-35, go through the suggestions listed below. Check all phone cord No dial tone Should the difficulty persist, connections. contact Ameriphone or your authorized dealer for No number No number stored in that assistance. dialed when memory memory button.See...
Regulatory Compliance The REN is used to determine Part 68 of FCC Rules Information the number of devices that may be connected to a telephone This equipment complies with line. Excessive RENs on a Part 68 of the FCC rules. On telephone line may result in the the bottom of this equipment is devices not ringing in response...
Page 28
If your home has specially please contact Walker / wired alarm equipment Ameriphone, 1-800-874-3005. connected to the telephone line, If the equipment is causing ensure the installation of this harm to the telephone network,...
Page 29
Regulatory Compliance disable your alarm equipment. corporation commission must If you have questions about give prior approval of what will disable alarm connection. equipment, consult your telephone company or a Part 15 of FCC Rules qualified installer. This Information telephone equipment is hearing aid compatible.
Page 30
Regulatory Compliance and can radiate radio (This increases the frequency energy and, if not separation between installed and used in the telephone equipment accordance with the and the receiver.) instructions, may cause 3. Connect the telephone harmful interference to radio equipment into an communications.
Page 31
Important Safety Regulatory Compliance Instructions Clarity, a Division of conditions may not prevent Plantronics, Inc. degradation of service in some 4289 Bonny Oaks Drive situations. Chattanooga, TN 37406 Telephone: 800-874-3005 Repairs to certified equipment should be made by an Industry Canada Technical authorized Canadian Specifications maintenance facility designated...
Page 32
Regulatory Compliance Important Instructions should contact the appropriate electric inspection authority, or electrician, as appropriate. The Ringer Equivalence Number is an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the...
Division of Plantronics, Inc. may replace it with a new or This warranty applies only to reconditioned product of the Ameriphone products that are same or similar design. purchased and used in the Repair or replacement will be United States or Canada.
Page 34
Warranty limitations on how long an address, phone number, implied warranty lasts or the proof of date of purchase, exclusion of incidental or and a description of the consequential damages, so problem. After repairing the the above exclusions or product, we, (or the service limitations may not apply to you.
Page 35
Warranty telephone systems or more sophisticated switching systems. If your JV-35 is not covered by this warranty, call (800) 426-3738 for advice as to whether we will repair your JV-35 and other repair information. The repair shall be warranted for 90 days.
Important Instructions Specifications - JV-35 DECIBEL GAIN Maximum gain: 37dB at 3000Hz (Volume at Maximum setting and Tone at High setting) PHYSICAL DIMENSIONS Size: 9.5" x 7" x 3.25" Weight: 2.52 lbs. POWER AC Adapter 4 AA Alkaline non-rechargeable batteries (not included)
Need help?
Do you have a question about the The Talking Phone and is the answer not in the manual?
Questions and answers