Friedrich Kuhl SS08 Installation And Operation Manual

Conditioner with heat pump

Advertisement

Room Air Conditioners
Standard Chassis Models
115-Volt:
208-230-Volt:
115-Volt:
208-230-Volt:

Table of Contents

Safety Precautions ................................................................................................................................................................................................................... 4
Unpacking Instructions............................................................................................................................................................................................................. 5
WARNING: Before Operating Your Unit .................................................................................................................................................................................. 6
Standard Filter Cleaning / Installation Instructions .................................................................................................................................................................. 7
Premium Carbon Filter Installation Instructions ....................................................................................................................................................................... 8
Control Panel Operation ......................................................................................................................................................................................................... 9
Control Options ...................................................................................................................................................................................................... 10
Control Panel Operation Instructions ............................................................................................................................................................................
Remote Control Operation ..................................................................................................................................................................................................... 20
Remote Effectiveness ............................................................................................................................................................................................................ 20
.......................................................................................................................................................................................... 22
Installation Instructions .......................................................................................................................................................................................................... 23
Standard Window Installation ................................................................................................................................................................................................ 25
Cord Routing Change ............................................................................................................................................................................................................ 34
Through-the-Wall Installation ................................................................................................................................................................................................. 36
Final Inspection & Start-up Checklist..................................................................................................................................................................................... 40
Routine Maintenance ............................................................................................................................................................................................................. 41
Service and Assistance ......................................................................................................................................................................................................... 41
Available Accessories ............................................................................................................................................................................................................ 41
Troubleshooting Tips .............................................................................................................................................................................................................. 42
Addendum 1 ........................................................................................................................................................................................................................... 44
Warranty ..... ........................................................................................................................................................................................................................... 45
SS08, SS10, SS12, SS14, SM15
SS12, SS16, SM18, SM21, SM24
SL22, SL24, SL28, SL36
YS10
ES12, ES16, YS12, EM18
YM18, EM24, EL36, YL24
................... 11
your unit to assure quiet operation, the greatest circulation of cool, dry air, and the most economic operation.
THANK YOU, on behalf of our entire company,
for making such a wise purchase.
UL
Safety Precautions
Your safety and the safety of others are very important.
WARNING
CAUTION
NOTICE
Register your air conditioner
Model information can be found on the name
plate behind the front cover.
Please complete and mail the owner
registration card furnished with this product,
or register online at www.friedrich.com.
For your future convenience, record the
model information here.
MODEL NUMBER
SERIAL NUMBER
PURCHASE DATE
WARNING
Refrigeration system
under high pressure

Advertisement

Table of Contents
loading

Summary of Contents for Friedrich Kuhl SS08

  • Page 1: Table Of Contents

    Model information can be found on the name plate behind the front cover. Please complete and mail the owner registration card furnished with this product, or register online at www.friedrich.com. For your future convenience, record the model information here. Standard Chassis Models...
  • Page 2: Unpacking Instructions

    Test the power cord Figure 1 All Friedrich room air conditioners are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI device on the end of the cord meets the UL and NEC requirements for cord connected air conditioners.
  • Page 3: Control Panel Operation

    20% intensity. After an additional 120 seconds, the display switches off. Touching any button automatically changes the display to 84°F after typical working hours and on weekends when commercial spaces retailers or www.friedrich.com. See FriedrichLink™ Adapter section on to full brightness.
  • Page 4 To switch from degrees Fahrenheit (F) to Celsius (C), press & buttons for three seconds. AUTO FAN SET POINT This means there is a compressor demand but the system is not ready The 2 indicates a DIM setting of 20%. Press the TIMER SET button within Use the buttons to adjust the minutes.
  • Page 5: Remote Control Operation

    Timer ON Scenarios Schedule ON Scenarios Scenario 1 AUTO FAN AUTO FAN AUTO FAN AUTO FAN SET POINT SET POINT SET POINT SET POINT The display returns to normal once the settings are saved. If the Timer function is turned ON during the ON time, the Timer The display shows a normal system.
  • Page 6: Installation Instructions

    Airflow Selection and Adjustment Figure 14 Figure 12 Air flow direction adjustment AUTO left or right side of the discharge opening. Each of the banks of louvers AUTO FAN CONTINUOUS can be directed left, right, up or down in order to achieve the most optimum AUTO move it in the direction that you would like the air to be directed.
  • Page 7: Standard Window Installation

    Standard Window Installation NOTE: DO NOT LEVEL the cabinet from front to back. Make sure there Figure 16 CAUTION is approximately 3/8” to 1/2” slope (1/8 to 1/4 bubble on level) toward the outside of the house. NOTE: Hardware and accessories used during installation are shown on page 23.
  • Page 8 Figure 22 Figure 24 Figure 23 STEP 10. Figure 27 CAUTION Cut/Sever Although great care has been taken to minimize sharp edges in the construction of your unit, use gloves or other hand protection when handling unit Failure to do so can result in minor to moderate personal injury.
  • Page 9: Through-The-Wall Installation

    OPTIONAL: e t i xits the left Use Tool Provided side of the unit at the bottom. At the consumer’s discretion, the supply cord can be routed to exit the right side of the unit. Please use the provided tool to attach the decorative front to the chassis. To do this, route the supply cord to the right side.
  • Page 10: Final Inspection & Start-Up Checklist

    Figure 46 Noises All air conditioners make some noise. Friedrich units are designed to operate as quietly as possible. An air conditioner mounted in a wall is quieter than one mounted in a window. It is important to ensure that the chassis seal gasket (Item 13) is properly installed (refer to installation instructions).
  • Page 11: Routine Maintenance

    KWIKS – For all ES and YS models. KWIKM – For all EM and YM models. KWIKL – For all EL and YL models. See www.friedrich.com for additional accessories for your unit. Addendum 1 The outside temperature is below Schedule Table with Energy Saving Values cooling mode when the outside temperature is and the unit may be damaged.
  • Page 12: Warranty

    FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service Agency that exceeds 25 miles one way will be the responsibility of the owner.

Table of Contents