Toshiba PDP002Z Function Manual page 15

Profibus-dp option
Table of Contents

Advertisement

PNU (the parameter number)
PNU
R/W
data type
915
R/W
Array [10]
Unsigned16
916
R/W
Array [10]
Unsigned16
918
R
Unsigned16
927
R/W
Unsigned16
928
R/W
Unsigned16
929
R
Unsigned16
939
R/W
Unsigned16
940
R/W
Unsigned16
941
R/W
Unsigned16
942
R/W
Unsigned16
943
R/W
Unsigned16
947
R
Array [64]
Unsigned16
963
R
Unsigned16
964
R
Unsigned16
965
R
Octet String2
967
R
Unsigned16
968
R
Unsigned16
PNU 915, IND 1 = the inverter parameter f831
PNU 915, IND 2 = the inverter parameter f832
PNU 915, IND 3 = the inverter parameter f833
PNU 915, IND 4 = the inverter parameter f834
PNU 915, IND 5 = the inverter parameter f835
PNU 915, IND 6 = the inverter parameter f836
PNU 916, IND 1 = the inverter parameter f841
PNU 916, IND 2 = the inverter parameter f842
PNU 916, IND 3 = the inverter parameter f843
PNU 916, IND 4 = the inverter parameter f844
PNU 916, IND 5 = the inverter parameter f845
PNU 916, IND 6 = the inverter parameter f846
Station address monitor (same as the inverter parameter f853).
Operator control rights (parameter identification, PKW).
: Mode
Value
:
0
Parameters cannot be written, only read
(927 can be written).
1: Parameters can be written and read (default).
Control rights (process data, PZD).
: Mode
Value
0: PZD part is disabled.
i.e. Receipt of new PZD data is ignored.
1: PZD part is enabled (default).
Selected PPO-type (same as the inverter parameter f830)
Value: PPO TYPE
1: PPO TYPE 1
2: PPO TYPE 2
3: PPO TYPE 3
4: PPO TYPE 4
OUT1 output terminal selection (same as f130).
Monitor is enabled using Status word bit 11.
OUT2 output terminal selection(same as f131).
Monitor is enabled using Status word bit 12.
FL output terminal selection (same as f132).
Monitor is enabled using Status word bit 13.
OUT3 output terminal selection (same as f133).
Monitor is enabled using Status word bit 14.
OUT4 output terminal selection (same as f134).
Monitor is enabled using Status word bit 15.
Fault number
PNU 947, IND 1 = fc90 (Active fault)
PNU 947, IND 9 = fe10 (Last ackn. fault)
PNU 947, IND 17 = fe11 (Second last ackn. fault)
PNU 947, IND 25 = fe12 (Third last ackn. fault)
PNU 947, IND 33 = fe13 (Fourth last ackn. fault)
Detected baud rate (same as f854):
0 =
12 Mbit/s
1 =
6 Mbit/s
2 =
3 Mbit/s
3 =
1.5 Mbit/s
4 =
500 kbit/s
5 = 187.5 kbit/s
6 = 93.75 kbit/s
7 = 45.45 kbit/s
8 =
19.2 kbit/s
9 =
9.6 kbit/s
255 = Invalid baud rate
Identification number of the PDP002Z (0x093C)
Profile number of the PDP002Z (0x0302)
Control word
Status word
- 14 -
E6581343 ③