14.5 Gas burners for NATURAL GAS G20 2.0 kPa
BURNER
Triple Crown
Rapid
Semi-rapid
Auxiliary
14.6 Gas burners for LPG G30 2.8-3.0 kPa
BURNER
Triple Crown
Rapid
Semi-rapid
Auxiliary
14.7 Gas connection
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
metallic pipes, make sure they do not
come in touch with mobile parts and
they are not squeezed.
14.8 Flexible nonmetal pipes
connection
If you have an easy access to the
connection, you can use a flexible pipe.
The flexible pipe must be tightly
attached by clamps.
NORMAL POWER
kW
4.0
3.0
2.0
1.0
NORMAL POWER
kW
4.0
3.0
2.0
1.0
REDUCED POWER kW
1.8
0.75
0.45
0.35
REDUCED POWER kW
1.8
0.72
0.43
0.35
In installation always use the pipe holder
and the gasket. The flexible pipe can be
applied when:
• it can not get hotter than room
temperature, higher than 30 °C,
• it is not longer than 1500 mm,
• it has no narrowing anywhere,
• it is not twisted or tighten,
• it does not get in touch with sharp
edges or corners,
• it's conditions can be easily checked.
When checking the flexible pipe make
sure:
• it does not show cracks, cuts, marks of
burnings on the two ends and on its
full length,
• the material is not hardened, but
shows its correct elasticity,
• the fastening clamps are not rusted,
• expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.
The gas supply ramp is on the rear side
of the control panel.
INJECTOR MARK
1/100 mm
146
119
96
70
INJECTOR MARK
1/100 mm
101
88
71
50