Page 1
AUTO - SCANNING WITH DIGITAL CONTROL LCD COLOR MEDICAL MONITOR AMM190WTD2 Operation Manual For future reference, record the serial number of your display monitor in the space below : Serial Number The serial number is located on the back of the monitor...
Page 3
Contents AMM190WTD2 Operation Manual................AMM190WTD2 Gebruikershandleiding..............AMM190WTD2 Manuel d’exploitation............... AMM190WTD2 Benutzerhandbuch................AMM190WTD2 Manuale di funzionamento.............. AMM190WTD2 Brukerveiledning................AMM190WTD2 Användarhandbok................AMM190WTD2 Manual de Operações............... AMM190WTD2 Manual de funcionamiento............. AMM190WTD2 Operation Manual................AMM190WTD2 取扱説明書..................AMM190WTD2 操作手册..................AMM190WTD2 Accessory Item List...............
Page 5
ADVAN INT’L CORP.2012 All other trademarks are the property of their reference owners. This document is subject to change without notice. Advan provides this information as reference only. Reference to other vendor’s products does not imply any recommendation or endorsement. Revision Control Document number REV.A 070512...
Monitor signals and function items............. DDC ......................Installation ....................Connecting the Power Cord ..............User Function / Messages................OSD Section ....................Troubleshooting ..................Specification of (AMM190WTD2) .............. Classification ..................... Electromagnetic Compatibility ..............Dimension Drawing (mm) of AMM190WTD2..........Connectors ....................Description of Warranty ................
Please check the following items are present when you unpack the box, and save the packing materials in case you will need to ship or transport the monitor in future. • AMM190WTD2 LCD Monitor and two video cables (1) HD15 VGA cable (1) DVI-D cable •...
Product(s), therefore, may not agree in detail to the published design or specifications. All specifications are subject to change without notice. Please contact ADVAN Int’l Corp directly or phone your local ADVAN Int’l Corp sales representative or agent for information on changes and new products.
Page 9
AMM190WTD2 5 Warnings 1. Read the operating manual thoroughly and be familiar with its contents prior to using this equipment. 2. Carefully unpack the unit and check if any damage occurred during shipment. 3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked by qualified personnel before operating it any further.
Page 10
Cautions 1. The AC Adapter must be plugged into a Grounded power outlet. 2. Use only the proprietary AMM190WTD2 power supply for the AMM190WTD2 monitor. Make a proper connection by ensuring that the shrink tubing completely secures the connection between the DC power cord and the extension cord.
AMM190WTD2 7 Symbol Definitions Dangerous: High Voltage Direct Current Serial Number This way up Fragile, handle with care Stacking limit by number Keep dry Recyclable Consult accompanying documents. Indicates proof of conformity to applicable European Economic Community Council directives and to harmonized standards published in the official journal of the European Communities.
A Declaration of Conformity has been filed for this product. A sample of this document may be found in the addendum which accompanied this manual. For a copy of the Declaration of Conformity document, please contact ADVAN Int’l Corp. and request for AMM190WTD2 DOC. Prepare for Unpack Before you unpack your monitor, prepare a suitable workspace.
AMM190WTD2 9 SAFETY PRECAUTION · Avoid placing the monitor, or any other heavy object, on the power cord to prevent fire or electrical shock from damage to the power cord. · Do not expose the monitor to rain, excessive moisture, or dust to avoid fire or shock hazard.
LED blinks for 1 seconds On and 1 second Off. The screen is displayed after the vertical and horizontal sync signals are restored. Power Management System The AMM190WTD2 Medical Monitor power management proposal. Provides four phases of power-saving modes by detecting the horizontal sync signal as shown in the table below.
AMM190WTD2 13 PIP / POP / PBP function The following combination options are available to you: Component Main SDI1 SDI2 C-Video / RGBs SDI1 SDI2 C-Video Component / RGBs...
User’s Guide Monitor input signals and function items Component Video Brightness Contrast Phase Chroma H/V Sharpness Scale Mode Color Space Zoom / Pan Multi Display H/V Position Freqency Phase Noise Reduc- tion Motion Offset DPMS Auto Source Select Key Lock Over Scan...
AMM190WTD2 15 To make your installation easier, the monitor is able to Plug and Play with your system if your system also supports DDC protocol. The DDC (Display Data Channel) is a communication protocol through which the monitor automatically informs the host system about its capabilities, for example, supported resolutions and corresponding timing.
UL Listed Detachable power supply cord with NEMA configuration 6-15P type (tandem blades) plug cap. Extension power cord (optional) Manufacturer: Bridgepower Model No: CB-1501047004 (5ft) or CB-1501047005 (15ft) or Hospital-grade CB-1501047006 (75ft) power cord Power Supply Model No: JMW1100KA1800F01 or AMM190WTD2 JMW1100KB1800F01...
AMM190WTD2 17 User Functions / Messages Key Name and Function Power LED : Lights up to indicate the power is turned ON. Power Switch : To power ON or OFF the monitor. Rotary switch : With the OSD menu activated, increases the value of the selected (Ture Right) parameter or moves rightward in OSD menu.
User’s Guide OSD Section Main Menu Chromatic Adjust Color Temp, Gamma Visual Adjust Brightness, Contrast, Phase, Chroma, Sharpness-H, Sharpness-V Setting Adjust Scale Mode, Color Space, Mirror, Freeze Frame, Zoom / Pan, PIP, POP, PBP Advanced Adjust OSD Position Control, Screen Control, DPMS, Auto Source Select, Smart Select, Restore Factory, Key Lock Information Adjust Custom Entry, SN, Run Time, Input Format...
Page 23
AMM190WTD2 19 OSD Section Chromatic Color Temp Change the color temperature - D65, D93, S1, S2 Gamma Change the gamma value - 1.8, 1.9, 1.95, 2.1, 2.1S, 2.2, 2.3, 2.4, 2.4S, S0, Radio graph Exit Exit the menu Visual Brightness...
Page 24
User’s Guide OSD Section Setting Scale Mode Change the scale mode - Fill all, One to One, Vertical - fill, Horizontal - fill, Fill aspect ratio Color Space Change color space between RGB and YPbPr available for Component and RGBS Mirror Off / On mirror image Freeze Frame...
Page 25
AMM190WTD2 21 OSD Section Sub menu of PIP Mode PIP Mode ON / Off Source PIP sub screen source - SDI1,2, C-Video, S-Video, Component, VGA, DVI, SOG Position PIP sub screen position - Top L, Top R, Bottom L, Bottom R...
Page 26
User’s Guide OSD Section Sub menu of POP Mode POP Mode ON / Off Source POP sub screen source - SDI1,2, C-Video, S-Video, Component, VGA, DVI, SOG Position POP sub screen position - Top L, Top R, Bottom L, Bottom R Size POP sub screen size - Small, Medium, Large, Full Blending...
Page 27
AMM190WTD2 23 OSD Section Advanced OSD Position Change the OSD menu - Position, Background, Control OSD time out, Language Screen Control Control and adjust H and V position, Freqency, Phase Noise Reduction, Motion Offset DPMS Change the DPMS Auto Source...
Page 28
User’s Guide OSD Section Sub menu of OSD Control H-position Adjust OSD H - position (Range 0 - 100) V-position Adjust OSD V - position (Range 0 - 100) Back ground Adjust transparency of OSD back ground (Range 0 - 100) OSD Time out Adjust OSD time out - 5s, 10s, 15s, 20s, 1m, 2m Language...
Page 29
AMM190WTD2 25 OSD Section Information Custom Entry Change the user or monitor’s name Display the serial number Run Time Display the total run time Input Format Display the current input resolution and vertical frequency Exit Exit the menu...
User’s Guide TROUBLESHOOTING Before sending your LCD monitor for servicing, please check the troubleshooting list below to see if you can self-diagnose the problem. Problems Current Status Remedy No Picture LED ON · Using OSD, adjust brightness and contrast to maximum or reset to their default settings.
AMM190WTD2 27 SPECIFICATION Model AMM190WTD2 LCD Panel 19 TFT LCD Panel Type Active Matrix Resolution 1680 x 1050 @ 60Hz Pixel Pitch 0.243575 X 0.24375 mm Display Color 16.7M colors Color Tone Up to 256 color tone Response Time <25ms Typ.
51LJ Medical Equipment E215822 This monitor is intended for use in Health Care Facilities model AMM190WTD2 Equipment is not suitable for use in the presence of flammable anesthetic mixture with air or with oxygen or nitrous oxide. No user serviceable parts inside, ask qualified personnel when accessing inside.
Consult the tables below for guidance in placing the AMM190WTD2. Manufacturer’s declaration - electromagnetic emission The Model AMM190WTD2 is intended for use in the electromagnetic environment specified below. The customer or the user of AMM190WTD2 should assure that it is used in such an environment. Emission test Compliance...
Page 34
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be con- sidered. If the measured field strength in the location in which the AMM190WTD2 is used exceeds the applicable RF compliance level above, the AMM190WTD2 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the AMM190WTD2.
Page 35
Recommended Separation Distances Between Portable and Mobile RF Communications Equi- pement and the AMM190WTD2 System The AMM190WTD2 system is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The user of the AMM190WTD2 system can help prevent electromagnetic...
ADVAN standards, quality and specifications. Subject to the conditions and limitations set forth below, ADVAN will, at its option, either repair any component of its products that prove defective by reason of improper workmanship or materials or ADVAN has the exclusive right to replace with refurbished units or with an equivalent product.
Page 39
ADVAN or its ASC without prior authorization. Buyer will be responsible for packaging (preferably original container) and shipping the defective goods to ADVAN or its ASC, shipping charges prepaid. ADVAN or its ASC will return the in warranty product, at no cost to the buyer.
Page 40
(out-of-warranty). Buyer must notify ADVAN or its ASC of the defect and request an RMA number. If the configuration has been modified in any manner, the product must be returned to its original configuration before any service will be performed by ADVAN or its ASC.
Page 41
ARE THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF WARRANTY OR ANY OTHER LEGAL THEORY. TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW, ADVAN SHALL NOT BE LIABLE TO THE PURCHASER OR END USER CUSTOMER OF AN ADVAN PRODUCT FOR ANY DAMAGES,...
Page 42
14-24 삼보호정빌딩 2층 210호 Tel : 02.783.5197 Fax : 02.783.5196 Web Page : http://www.advancorp.com Manufacture ADVAN INT’L CORP 47817 Fremont Blvd. Fremont, CA 94538, USA Tel : 1 510 490 1005 Fax : 1 510 490 1151 Web Page : http://www.advancorp.com...