Adaptation To Different Types Of Gas - Smeg TRA93P User Manual

Hide thumbs Also See for TRA93P:
Table of Contents

Advertisement

When the job is complete, the installer must
issue a certificate of conformity.
1 Extraction using a hood
2 Extraction without a hood
A Single natural draught chimney
B Single chimney with extractor fan
C Directly outdoors with wall- or window-
mounted extractor fan
D Directly outdoors through wall
Air
Combustion products
Extractor fan
Installation

5.2 Adaptation to different types of gas

The appliance is preset for natural
gas G20 at a pressure of 20
mbar.
In case of operation with other types of gas,
the burner nozzles must be changed and
the minimum flame adjusted on the gas
taps.
Replacing nozzles
1. Remove the pan stands, burner caps and
flame-spreader crowns to access the
burner casings.
2. Replace the nozzles using a 7 mm
spanner according to the gas to be used
(see Burner and nozzle characteristics
tables).
1. Internal nozzle
2. External nozzle
3. Replace the burners in the correct
position.
77