Axis ExCam XPT Q6075 User Manual page 32

Ptz network camera
Hide thumbs Also See for ExCam XPT Q6075:
Table of Contents

Advertisement

AXIS Q60 Series
Specifications
Function
0 V DC (-)
DC output
Configurable (Input
or Output)
1
0 V DC (-)
2
DC output 3.3 V, max 250 mA
A
I/O configured as input
B
I/O configured as output
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–6
Digital input – Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.
Digital output – Internally connected to pin 1 (DC
ground) when active, and floating (unconnected) when
inactive. If used with an inductive load, e.g. a relay, a
diode must be connected in parallel with the load, for
protection against voltage transients.
32
Specifications
3.3 V DC
Max load = 250 mA
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q6074Q6075Q60 seriesD201-s xpt q6075

Table of Contents