Air to Water Heat Pump split system
ErP performance values
• ErP Definition
"ErP" includes two directives that are part of the program for the reduction of green house gas emission :
- Eco-design directive sets effiency thresholds and prohibits the sale of any product with efficiency lower than the set thresholds.
- According to labelling directive, energetic efficiency shall be displayed to encourage end-users to purchase energy-efficient products.
• Package (High power models)
" Application 35°C
Models
Hydraulic unit reference
Seasonal space heating energy efficiency of
heat pump
Type of temperature control (* = Outdoor
sensor ; ** = Room unit )
Bonus
Seasonal space heating energy efficiency of
package under average climate
Energy class of package
Seasonal space heating energy efficiency of
package under warmer climate
Seasonal space heating energy efficiency of
package under colder climate
The energy efficiency of the package of products provided for in this fiche may not correspond to its actual energy efficiency once installed in
a building, as the efficiency is influenced by further factors such as heat loss in the distribution system and the dimensioning of the products in
relation to building size and characteristics.
Electrical back up heater consumption is taken into account in the performance calculation.
" Application 55°C
Models
Hydraulic unit reference
Seasonal space heating energy efficiency of
heat pump
Type of temperature control (* = Outdoor
sensor ; ** = Room unit )
Bonus
Seasonal space heating energy efficiency of
package under average climate
Energy class of package
Seasonal space heating energy efficiency of
package under warmer climate
Seasonal space heating energy efficiency of
package under colder climate
The energy efficiency of the package of products provided for in this fiche may not correspond to its actual energy efficiency once installed in
a building, as the efficiency is influenced by further factors such as heat loss in the distribution system and the dimensioning of the products in
relation to building size and characteristics.
Electrical back up heater consumption is taken into account in the performance calculation.
- 76 -
G
F
E
D
< 55%
≥ 55%
≥ 59%
≥ 61% ≥ 100% ≥ 107% ≥ 115% ≥ 123% ≥ 150% ≥ 175%
HP 11 Single
Waterstage ...
phase
WSYG140DG6
151%
* classe
** classe
II
VI
2%
4%
153%
155%
A++
A++
173%
175%
123%
125%
G
F
E
D
< 30%
≥ 30%
≥ 34%
≥ 36%
HP 11 Single
Waterstage ...
phase
WSYG140DG6
112%
* classe
** classe
II
VI
2%
4%
114%
116%
A+
A+
122%
124%
102%
104%
C
B
A
A
+
HP 14 Single
HP 11
phase
3-Phase
WSYG140DG6
WSYK160DG9
148%
154%
* classe
** classe
* classe
II
VI
II
2%
4%
2%
150%
152%
156%
A++
A++
A++
178%
180%
207%
120%
122%
126%
C
B
A
A
+
≥ 75%
≥ 82%
≥ 90%
≥ 98% ≥ 125% ≥ 150%
HP 14 Single
HP 11
phase
3-Phase
WSYG140DG6
WSYK160DG9
113%
112%
* classe
** classe
* classe
II
VI
II
2%
4%
2%
115%
117%
114%
A+
A+
A+
121%
123%
138%
102%
104%
102%
Installation and operating manual "1765 - EN"
A
A
++
+++
HP 14
3-Phase
WSYK160DG9
WSYK160DG9
150%
** classe
* classe
** classe
* classe
VI
II
VI
4%
2%
4%
158%
152%
154%
151%
A++
A++
A++
209%
198%
200%
190%
128%
124%
126%
121%
A
++
A
+++
HP 14
3-Phase
WSYK160DG9
WSYK160DG9
117%
** classe
* classe
** classe
* classe
VI
II
VI
4%
2%
4%
116%
119%
121%
119%
A+
A+
A+
140%
139%
141%
143%
104%
102%
104%
102%
HP 16
3-Phase
149%
** classe
II
VI
2%
4%
153%
A++
A++
192%
123%
HP 16
3-Phase
117%
** classe
II
VI
2%
4%
121%
A+
A+
145%
104%

Hide quick links: