Air to Water Heat Pump split system
" Model single phase
" Model single phase
Hydraulic unit
Hydraulic unit
1 2 3
1 2 3
4
5
External component
External component
contact *
contact *
N
L
" Model 3-phase
" Model 3-phase
Hydraulic unit
Hydraulic unit
1 2 3
1 2 3
4
5
6
1
2
3
4
5
6
L1 L2 L3
COMMUN
External component
External component
contact *
contact *
L1 L2 L3
Installation and operating manual "1765 - EN"
4
5
6
6
Electrical back-up
supply 230 V
single phase
4
5
6
Electrical back-up
supply 400 V
3-phase
figure 38 - Connection to terminal block and power relays
Outdoor unit single phase
Outdoor unit single phase
Green / yellow
Green / yellow
Brown
Brown
Blue
Blue
Red
Red
Interconnection
Interconnection
between the outdoor unit
between the outdoor unit
and the hydraulic unit
and the hydraulic unit
Outdoor unit 3-phase
Outdoor unit 3-phase
1 2 3 L1 L2 L3 N
1 2 3 L1 L2 L3 N
Green / yellow
Green / yellow
Brown
Brown
Blue
Blue
Red
Red
Interconnection
Interconnection
between the outdoor unit
between outdoor unit and
and the hydraulic unit
hydraulic unit
L N
L N
Electricity supply
Electricity supply
230 V single phase
230 V single phase
L1 L2 L3 N
L1 L2 L3 N
Electricity supply
Electricity supply
400 V 3-phase
400 V 3-phase
- 37 -